Datasheet

For more information, visit http://apac.idec.com
B-125
APEM
Switches &
Pilot Lights
Control Boxes
Emergency
Stop Switches
Enabling
Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit
Protectors
Power Supplies
LED Illumination
Controllers
Operator
Interfaces
Sensors
AUTO-ID
Switches & Pilot Lights
Flush Silhouette
ø16
ø22
ø30
Miniature
Pilot Lights
CW
LW-F
LB
LBW
UP
Flush Bezel
LB/LBW Series
Accessories
Package Quantity:1
Shape Specication Part No. Ordering No.
Package
Quantity
Remarks
Locking Ring Wrench
Metal
(Nickel-plated
brass)
MT-001 MT-001 1
Used to tighten the locking ring when
installing the units on to the panel.
For Standard Bezels
Lens Removal Tool
Stainless
Steel
MT-101 MT-101 1
Used to remove the lens or button.
(for standard bezels)
Switch Guard (spring return)
180° Spring return
Spring return
For round / square
units
(LB1/LB2)
Guard
(Polyacetal)
Base
(Polyarylate)
AL-K6SP AL-K6SP 1
Degree of protection: IP65
Used to protect pushbuttons and
illuminated pushbuttons from
inadvertent operation.
See B-127 for dimensions.
With the gasket mounted on the
switch, attach the switch guard and
mount on the panel.
For rectangular
units
(LB3/LB4)
AL-KH6SP AL-KH6SP 1
180° Spring return
for Single Board Mounting
Spring return
For rectangular
units
(LB3/LB4)
Guard
(Polyacetal)
Base
(Polyarylate)
LA9Z-K3 LA9Z-K3 1
Degree of protection: IP65
With the gasket mounted on the
switch, attach the switch guard and
mount on the panel.
See B-127 for dimensions.
Switch guard (remains open)
Remains 110°/180° open
(Can be used for single
board mounting)
110°
180°
For round / square
units
(LB1/LB2)
Guard
(Polyacetal)
Base
(Polyarylate)
LB9Z-K2 LB9Z-K2 1
Degree of protection: IP40
Used to protect pushbuttons and
illuminated pushbuttons from
inadvertent operation.
See B-127 for dimensions.
With the gasket mounted on the
switch, attach the switch guard and
mount on the panel.
See B-136 for dimensions.
When using for single board
mounting, remove the rubber gasket
from the switch.
For rectangular
units
(LB3/LB4)
LB9Z-K3P LB9Z-K3P 1
Degree of protection: IP65
With the gasket mounted on the
switch, attach the switch guard and
mount on the panel.
See B-127 for dimensions.
Rubber Boot
1. For round units
(LB1)
Rubber
(Transparent
silicon rubber)
LB9Z-D1 LB9Z-D1 1
Degree of protection: IP65
See B-127 for dimensions.
See B-135 for mounting.
2. For square units
(LB2)
LB9Z-D2 LB9Z-D2 1
3. For rectangular
units
(LB3/LB4)
LB9Z-D3 LB9Z-D3 1
Mounting Hole Plug
Metal
[Plug]
Metal
(Zinc diecast)
[Locking nut]
Polyacetal
[Gasket]
Nitrile rubber
AL-BM6 AL-BM6 1
Degree of protection: IP65
Tightening torque: 0.1 to 0.29 N·m
See B-127 for dimensions.
Mounting Hole Plug
Rubber
Nitrile rubber
(black)
AL-B6 AL-B6PN05 5
Degree of protection: IP65
See B-127 for dimensions.
ø18.0
60.0
60.0
For more information, visit http://eu.idec.com