Datasheet
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø22mm - HW Series
Switches & Pilot Devices
610
www.IDEC.com
1705151132
Standards & Approvals
Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
Approvals
Certicate No.
2005010305145656
File No. E68961
File No. LR92374
Registration No. R9551089 (E-stops)
Registration No. R50054316 (Dual Pushbuttons)
Registration No. J9650511 (Pilot Lights)
Registration No. J9551458 (all other switches)
CSA: pushbuttons and selector switches: A600
pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
UL: pushbuttons and selector switches: A600
pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB)
pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Electric Shock Protection Class 0 conforming to IEC60536
Degree of Protection
(conforming to IEC60529 and UL50)
UL Type 1, 4X, 12, 13
1
IP65 (from front of the panel) IP20 (Type HW-F contact block)
Pollution Degree (conforming to IEC60947-1) 3 for switches not using a transformer, 2 for switches using a transformer
External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1
Terminal Referencing Conforming to CENELEC EN50005
Contact Ratings
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors
Contact Block Type HW-C/HW-F /HW-G
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Contact Ratings by Utilization Category
IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Characteristics
Operational Voltage 24V 48V 50V 110V 220V 440V
Operational
Current
AC 50/60 Hz
AC-12 Control of resistive loads & solid state loads 10A — 10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A
DC
DC-12 Control of resistive loads & solid state loads 8A 5A — 2.2A 1.1A —
DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A —
For dimensions, see page 660.
Note 1. Except for HW[]F and HW2B
LED Lamp Ratings (LSTD Type)
Model
LSTD-6k LSTD-1k LSTD-2k LSTD-H2k LSTD-M4k
In place of k,
specify the Lens/LED
Color Code.
Lamp Base BA9S/13
Rated Voltage 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC
Voltage Range 6V AC/DC ±10% 12V AC/DC ±10% 24V AC/DC ±10% 120V AC ±5%
240V AC
±5%
Current
Draw
AC
A, R, W:
G, S:
17mA
8mA
11mA 11mA 10mA 10mA
DC
A, R, W:
G, S:
14mA
5.5mA
10mA 10mA – –
Color Code A (amber), G (green), R (red), S (blue), W (white)
Lamp Base Color Same as illumination color
Voltage Marking Die stamped on the base
Life (reference value) Approx. 50,000 hours (The luminance reduces to 50% the initial intensity when used on complete DC.)
Internal Circuit
A, R, W A, R, W
LED Chip
Protection Diode
Zener Diode
LED Chip
Protection Diode
Zener Diode
G, S
LED Chip
Protection Diode
Zener Diode