Dual Pushbuttons Instructions con’t
Replacement of Lamps
Lamps can be replaced by using the lamp holder tool (OR-55) from the front of
the panel, or by removing the contact block assembly from the operator unit.
Removing the Lamps from the Front of the Panel
Removal
1. To remove, slip the lamp
holder tool onto the lamp
head lightly. Then push
slightly, and turn the lamp
holder tool counterclock-
wise.
Installation
1. To install, insert the lamp
head into the lamp holder
tool, and hold the lamp as
shown in the gure below.
Lamp Lamp Holder Tool
2. Place the pins on the lamp
base to the grooves in the
lamp socket. Insert the lamp
and turn it clockwise.
Lamp Base
About Pushbutton Switches
The pushbuttons cannot be
removed or replaced!
Do not attempt to remove
using a at screwdriver or pin-
cers, otherwise the pushbut-
tons may be damaged.
Pushbuttons
Do not attempt
to remove the
pushbuttons!
Narrow Mounting
When mounting the units closely in a horizontal row on 30mm centers, use op-
tional barriers to prevent interconnection between adjoining terminals. The barri-
ers can be attached simply by pressing them onto the sides of contact blocks.
Barrier
30 30
When mounting transformer type illuminated
units closely in a horizontal row on 30-mm
centers, insert solid wires or stranded wires
into inside of the terminal screw on the
transformer (see gure on the right) to prevent
short circuit between adjoining terminals.
X2X1 X2X1
Inside Inside
Tightening Torque for Terminal Screws
Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m.
Installation of LED Illuminated Units
When using full voltage type LED illuminated units, provide protection against
electrical noise, if necessary.
Applicable Wiring
The applicable wire size is 2 mm
2
maximum. (solid wire ø1.6mm
2
maximum) One
or two wires can be connected.
Applicable Crimping Terminal
ø3.6 min.
7.9 max.
4 max. 5.5 min.
Be sure to use an insulation tube or cover on the crimping part of the crimping
terminal to prevent electrical shocks.
Solid Wire
8 max.
ø1.6 max.
Note: When connecting wires to contact blocks or transformers in the direction
shown below, keep the insulation stripping length 6.6 mm at the maximum.
X2X1 X2X1
Inside Inside
Installing the Rubber Cover
When using the HW7D pushbuttons in places where the pushbuttons are
subjected to water splash or an excessive amount of dust, make sure to use the
HW9Z-D7D rubber boot (IP65) which is ordered separately.
Notes for Installing the Rubber Cover
Remove the gasket from the operator, and install the rubber boot on the operator.
Pull out the seals of the rubber boot and place them around the operator sleeve
as shown. Make sure that the seals are not twisted or tucked inside and that
the gasket does not remain, otherwise the normal waterproof and dustproof
characteristics are not ensured.
Remove
Gasket
Install
1. Remove the gasket. 3. Rubber boot is
installed.
2. Install the rubber boot
on the pushbuttons.
Seals
Seals