Datasheet
16
HS6E Subminiture Interlock Switches with Solenoid
Dimensions
Interlock Switch •Mounting Hole Layout
30
20 to 22
20.5
28.5
41.8
(ø4.3 or M4 tapped hole)
3-M4 Screw
Hole for Manual Unlocking
ø12 (reference)
(ø4.3 or M4 tapped hole)
3-M4 Screw
Hole for Manual Unlocking
ø12 (reference)
20.5
20 to 22
30
28.5
41.8
Manual Unlocking Key
* Actuator center
1
1
20
(2.3)
C12
35
30
20.5
4
4
5.5
10.1*
15
10.4
15
4
4
75
R2.1
28.5
37
41.8
46.1
ø4.4
(22.5) (22.5)
Use three mounting screws to
install the interlock switch. The
switch cannot be installed
properly using only one or two
screws, resulting in possible
malfunction.
(12.6
±1
)*
22.6
±1
*
22.6
±1
*
Actuator Stop
(supplied) (Note1)
Actuator Stop
(supplied) (Note1)
Actuator Stop
(supplied) (Note1)
(5)
50.8
0.8
(14)
(14)
(6.2)
(42) (Note2)
0.8
0.8
48.8
(25)
0.8
Interlock Switch
Door Stop
Actuator Stop
HS9Z-A61 Actuator
Door Stop
When using straight actuator
(HS9Z-A61)
When using right-angle actuator
(HS9Z-A62S)
When using horizontal/vertical
angle adjustable actuator
(HS9Z-A65/A66)
Actuator Mounting Reference Position
As shown in the figure on the right, the mounting reference position of the
actuator when inserted in the interlock switch is:
The actuator stop on the actuator lightly touches the interlock switch.
Note: After mounting the actuator, remove the actuator stop from the actuator.
Note 1: Remove the actuator stop after mounting the actuator.
Note 2: 41.4 when using HS9Z-A62.
* The retention force of the HS9Z-A62 actuator is 100N. When
tensile force exceeding 100N is expected, use the HS9Z-A62S
actuator (with a mounting plate).