Datasheet
24
HS6E Subminiture Interlock Switches with Solenoid
Recommended Tightening Torque of Mounting Screws
• Interlock switch: 1.0 to 1.5 N·m (three M4 screws)
• Actuators: 1.0 to 1.5 N·m (two M4 screws)
• The above recommended tightening torques of the mounting
screws are the values with hex socket head bolts. When other
screws are used and tightened to a smaller torque, make sure
that the screws do not become loose after mounting.
• Mounting bolts are not supplied with the interlock and must be
supplied by the user.
• To avoid unauthorized or unintended removal of the interlock
switch and the actuator, it is recommended that the interlock
switch and the actuator are installed in an unremovable man-
ner, for example using special screws, rivets, or welding the
screws.
• When installing the HS9Z-A62S actuator, use the mounting
plate (supplied with the actuator) on the hinged door, and
secure the actuator tightly using two M4 screws.
• The mounting plate has orientation.
• Do not lose the mounting plate.
Cables
• Do not fasten or loosen the gland at the bottom of the inter-
lock switch.
• When bending the cable during wiring, make sure that the
cable radius is kept at 30 mm minimum.
• When wiring, make sure that water or oil does not enter from
the end of the cable.
• Do not open the lid of the interlock switch. Otherwise the
interlock switch will be damaged.
• The solenoid has polarity. Make sure of the correct polarity
when wiring.
Wire Identification
• Wires can be identified by the color and or a white line printed
on the wire.
No. Insulation Color No. Insulation Color
1 Blue/White 7 White
2 Gray 8 Black
3 Pink 9 Pink/White
4 Orange 10 Brown/White
5 Orange/White 11 Brown
6 Gray/White 12 Blue
Note: Wires of gray or gray/white are not used and should not be connected.
Jacket
Colored Insulation
87
96
32
5
1
4
12
11
10
Terminal Number Identification
• When wiring, identify the terminal number of each contact by
the color of insulation.
• The following table shows the identification of terminal num-
bers.
• When wiring, cut unused wires at the end of the jacket to
avoid incorrect wiring.
BlackWhite
Orange/White
Brown/White
Orange/White
Brown/White
Orange/White
Brown/White
22
Orange/White
Brown/White
Pink
Pink
Pink
Pink/White
Pink/White
Pink/White
Pink/White
Blue/White
Blue/White
Blue/White
Blue/White
Pink
ontact ArrangeentMoel
A1A2
(+) (–)
22
11
21
12 4241
5453
41 421211
11 12 4241
41 421211
21 22
51 52
51 52
Door Monitor Lock Monitor
Orange
Brown
Orange
Brown
Orange
Brown
Orange
Brown
Blue
Blue
Blue
Blue
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Main circuit:
Main circuit:
Main circuit:
Main circuit:
HS6E-L
HS6E-M
HS6E-N
HS6E-P
HS6E-VL
HS6E-VM
HS6E-VN
HS6E-VP
33 34
31 32
53 54
Pink/WhitePink
53 54
3433
2221
Orange/White
Brown/White
Gray Gray/White
11 4241
Orange
Brown
Blue
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
3231
22
Blue/White
12
21
3231
21
Pink/WhitePink
53 54
Orange/White
Brown/White
Gray Gray/White
11 4241
Orange
Brown
Blue
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
3433
22
Blue/White
12
21
Orange/White
Brown/White
Gray Gray/White
11 4241
Orange
Brown
Blue
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
3231
22
Blue/White
12
21
Pink Pink/White
5251
Orange/White
Brown/White
Gray Gray/White
11 4241
Orange
Brown
Blue
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
3433
22
Blue/White
12
21
Pink Pink/White
5251
Note: The contact arrangements show the contact status when the actuator
is inserted and locked.
M4 Tapped Hole
Hinged Door
M4 Screws
Mounting Plate (supplied)
Rubber Bushing
Gland
Gland
30 mm
Minimum Radius
(70)
(50)
30 mm
Minimum
Radius