Datasheet
Table Of Contents

3
HS5D Miniature Interlock Switches
Head removal detection for safer performance.
Specications
Applicable Standards
EN ISO14119
IEC60947-5-1
EN60947-5-1 (TÜV approval)
GS-ET-15 (TÜV approval)
UL508 (UL listed)
CSA C22.2 No. 14 (c-UL listed)
GB14048.5 (CCC approval)
IEC60204-1/EN60204-1
(applicable standards for use)
Type and Coded Level
Type 2 low level coded interlocking device
(ISO 14119)
Operating Temperature –30 to +70°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree 3
Impulse Withstand
Voltage
4 kV
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance
(500V DC megger)
Between live and dead metal parts:
100 MΩ minimum
Between terminals of different poles:
100 MΩ minimum
Electric Shock
Protection Class
Class II (IEC61140)
Degree of Protection IP67 (IEC60529)
Shock Resistance Damage limits: 1000 m/s
2
Vibration Resistance
Operating extremes:
10 to 55 Hz, amplitude 0.5 mm
Damage limits:
30 Hz, amplitude 1.5 mm
Actuator Operating
Speed
0.05 to 1.0 m/s
Direct Opening Travel 10 mm minimum
Direct Opening Force 50N minimum
Operating Frequency 900 operations per hour
Mechanical Durability 1,000,000 operations minimum (GS-ET-15)
Electrical Durability
100,000 operations minimum
(AC-12 250V, 6A)
1,000,000 operations minimum
(24V AC/DC,100 mA)
(operation frequency: 900 operations per hour)
Performance of
Terminals 11-12 of
Removed Head Unit
Mechanical damage limits: 10 operations min.
Insulation resistance: 100 MΩ (initial value)
Dielectric strength: 1000V, 1 minute (initial value)
Conditional
Short-circuit Current
100A (250V) (note)
Weight (approx.) Plastic head: 80g, Metal head: 110g
Note: Use a 250V/10A fast-blow fuse as a short-circuit protector.
Contact Ratings
Rated Insulation Voltage (Ui) 300V
Thermal Current (Ith) 10A
Rated Voltage (Ue) 30V 125V 250V
Rated
Current
(Ie) *
AC
Resistive load (AC-12) 10A 10A 6A
Inductive Load (AC-15) 10A 5A 3A
DC
Resistive load (DC-12) 8A 2.2A 1.1A
Inductive Load (DC-13) 4A 1.1A 0.6A
•Minimum applicable load (reference): 5V AC/DC, 1 mA
(Applicable range may vary with operating conditions and load types.)
*TÜV rating: AC-15 3A/250V, DC-13 4A/30V
•Head removal detection function turns OFF the main cir-
cuit (11-12) when the head of the HS5D is removed.
•3 contact types with dual enabling contacts and a monitor
contact are available. Can be installed in narrow spaces.
(30W × 30D × 91H mm)
•The actuator is interchangeable with HS5E and HS5L.
•Double insulation structure eliminates the need for ground-
ing.
•The head orientation can be rotated, allowing 8 different
actuator entries.
•Degree of protection (contacts): IP67 (IEC60529)
•NC contacts with direct opening action (IEC/EN60947-5-1)
•Proprietary actuators prevent invalidation of the contacts
(ISO14119).
•M3 terminal screws for easy wiring.
•Gold-plated contacts suitable for small loads.
Parts Description
Right-angle Actuator
(SUS304)
Angle
Adjustable
Actuator
(for hinged doors)
Right-angle Actuator
w/rubber bushing
Straight Actuator
(SUS304)
Straight Actuator
w/rubber bushing
M3 Terminal Screw
Gland Port
(Use conduits or
cable glands which
can maintain IP67
protection.)
Part No. Development
HS5D-11 Z RN M
Circuit Code
11: 1NO-1NC
02: 2NC
12: 1NO-2NC
03: 3NC
Head Material
blank: Plastic
Z : Metal
Head/Housing Color
RN: Red/Gray
Gland Port
blank: G1/2
P: PG13.5
M: M20
Note: Contact IDEC for KOSHA approved model.