Datasheet

28
HS5L Interlock Switches with Solenoid
Changing the cable orientation
(two-conduit model)
Cable orientation can be changed on two-conduit models
(HS5L-4SM-G/HS5L-4LSM-G). Straight, left, and right
orientation is available.
When shipped, the terminal cover is installed on the HS5L for
straight or left cable orientation.
See below for mounting the cable rightward.
Remove the cover mounting screws (M3×2) and remove the
HS5L from the cover.
Rotate the cover 180º.
Re-intall the cover on the HS5L and fasten using the cover
mounting screws.
Note: Before tightening the cover mounting screws, slide the
spacer in the direction opposite the screw positions to
prevent it from coming into contact with the screwdriver.
Interlock Switch
Terminal Cover
Spacer
Cover Mounting
Screws (M3×2)
180°

Opening conduit port
Before use, knock out the conduit port where the connector is to
be connected, using a tool such as screwdriver as shown in the
gures.
Before opening the conduit port, remove the terminal cover
from the HS5L, and remove the locking ring for the cable gland
installed in the terminal cover.
Be sure to remove any cracks or burrs on the conduit port, as it
will impair waterproof performance.
Interlock switch
Straight orientation
Side orientation
Locking ring
for cable gland
Terminal cover
Connector Wiring
Perform wiring according to following procedures to .
Insert the cable into the connector. Leave A and B untightened.
Open the cover and insert the cable into the cover.
Wire to the terminals.
Tighten in the order of A Cover B.
To remove the wiring, turn the power off and then unwire in the
order of B cover (waterproof gasket A).
Note: When removing A, because the waterproong gasket is
tightly attached to the cable, pull out the gasket carefully
with tweezers so that the gasket is not damaged before
loosening A. Otherwise, the cable will rotate together with A
when loosened, and might break due to excessive twisting.
Also, when reassembling, place the gasket in the original
position rst.
Safety Precautions
Interlock
switch
Spring clamp
terminal block
Spring clamp
terminal block
A
Waterproof
packing
Sheath
B
Cover
Spring clamp
erminal block
Gasket holds
the sheath
tightly
Make sure that the entire bore
surface of the gasket is in contact
with the sheath.
Sheath is
loose
When opening the cover, be
careful not to lose the cover
mounting screw.
When tightening connector
B, insert the cable into the
connector, and set it to a
position where the gasket of
the connector holds the cable
sheath, otherwise, its waterproof
performance might be impaired.
Tighten the connector in
order of A B. If connector
B is tightened rst, the wiring
connected to the spring clamp terminal may become twisted
when tightening A, causing disconnection or malfunction.
Tighten the connectors with tightening torque according to the
torque value recommended by the connector manufacturer.
Otherwise, waterproof performance might be impaired.
Do not exert excessive load, pressure, or tensile force on the
cable, otherwise, disconnection or malfunction might occur.
Interlock switch Cover
Waterproong
gasket
Waterproong
gasket
Connector (sold separately)
Connector (sold separately)
www.idec.com
USA IDEC Corporation Tel:
+1-408-747-0550
opencontact@idec.com
Germany
IDEC Electrotechnik GmbH
Tel: +49-40-25 30 54 - 0 service@eu.idec.com
Singapore IDEC Izumi Asia Pte. Ltd. Tel: +65-6746-1155
info@sg.idec.com
Thailand
IDEC Asia (Thailand) Co., Ltd
Tel: +66-2-392-9765 sales@th.idec.com
Australia IDEC Australia Pty. Ltd. Tel:
+61-3-8523-5900
sales@au.idec.com
Taiwan IDEC Taiwan Corporation Tel: +886-2-2698-3929 service@tw.idec.com
Hong Kong IDEC Izumi (H.K.) Co., Ltd. Tel: +852-2803-8989
info@hk.idec.com
China/Shanghai
IDEC (Shanghai) Corporation Tel:
+
86-21-6135-1515
idec@cn.idec.com
China/Shenzhen
IDEC (Shenzhen) Corporation
Tel: +86-755-8356-2977 idec@cn.idec.com
China/Beijing IDEC (Beijing) Corporation Tel: +86-10-6581-6131 idec@cn.idec.com
Japan IDEC Corporation Tel:
+81-6-6398-2527
marketing@idec.co.jp
Specications and other descriptions in this brochure are subject to change without notice.
2017 IDEC Corporation, All Rights Reserved.
EP1534-3 MARCH 2017
Head Office
6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan