Datasheet

88
HS1L Interlock Switches with Solenoid
Circuit Diagrams and Operating Characteristics
Spring Lock
Interlock Switch Status
Status 1 Status 2 Status 3 Status 4 Manual Unlock
•Door Closed
•Machine ready to
operate
•Solenoid de-energized
•Door Closed
•Machine cannot be
operated
•Solenoid energized
•Door Open
•Machine cannot be
operated
•Solenoid energized
•Door Open
•Machine cannot be
operated
•Solenoid de-energized
•Door Closed
•Machine cannot be
operated
•Solenoid de-energized
Door Status
UNLOCK
Unlock position
Circuit Diagram (HS1L-DQ4)
(–
)
(+)
A2
A1
34 63 64
5251
33
22
21
11
12 4241
(–
)
(+)
A2
A1
34 63 64
5251
33
2221
11 12 4241
(–
)
(+)
A2
A1
34 63 64
5251
33
22
21
11
12 4241
(–
)
(+)
A2
A1
34
63 64
52
51
33
22
21
11
12 4241
(–
)
(+)
A2
A1
34 63 64
5251
33
22
21
11
12 4241
Door
Closed (locked) Closed (unlocked) Open Open Closed (unlocked)
Contact Configuration
HS1L-DQ4
63 64
3433
2221
11 12 4241
(+)
A2
(–)
A1
Door Monitor
(Actuator
inserted)
Lock Monitor
(Solenoid
OFF)
Monitor Circuit:
Monitor Circuit:
Main Circuit
:
Main Circuit
:
5251
(+)
X2
(–)
X1
LED
Main Circuit
11–42
ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Main Circuit
21–52
ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor
Circuit
(Door Open)
33–34
OFF (open) OFF (open) ON (closed) ON (closed) OFF (open)
Lock Monitor
Circuit
(unlocked) 63-64
OFF (open) ON (closed) ON (closed) ON (closed) ON (closed)
Solenoid Power A1-A2
OFF (de-energized) ON (energized) ON (energized) OFF (de-energized) OFF (de-energized)
Solenoid Lock
Interlock Switch Status
Status 1 Status 2 Status 3 Status 4 Manual Unlock
•Door Closed
•Machine ready to
operate
•Solenoid energized
•Door Closed
•Machine cannot be
operated
•Solenoid de-energized
•Door Open
•Machine cannot be
operated
•Solenoid de-energized
•Door Open
•Machine cannot be
operated
•Solenoid energized
• Door Closed
• Machine cannot be
operated
• Solenoid de-energized
to energized
Door Status
UNLOCK
Unlock position
Circuit Diagram (HS1L-DQ7Y)
(–
)
(+)
A2
A1
34 63 64
5251
33
22
21
11
12 4241
(–
)
(+)
A2
A1
34 63 64
5251
33
22
21
11
12 4241
(–
)
(+)
A2
A1
34 63 64
5251
33
22
21
11
12 4241
(–
)
(+)
A2
A1
34
63 64
52
51
33
22
21
11
12 4241
(–
)
(+)
A2
A1
34 63 64
5251
33
2221
11 12 4241
Door
Closed (locked) Closed (unlocked) Open Open Closed (unlocked)
Contact Configuration
HS1L-DQ7Y
63 64
3433
2221
11 12 4241
5251
(+)
A2
(–)
A1
Lock Monitor
(Solenoid
ON)
Monitor Circuit:
Monitor Circuit:
Main Circuit
:
Main Circuit
:
(+)
X2
(–)
X1
Door Monitor
(Actuator
inserted)
LED
Main Circuit
11–42
ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Main Circuit
21–52
ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor
Circuit
(Door Open)
33–34
OFF (open) OFF (open) ON (closed) ON (closed) OFF (open)
Lock Monitor
Circuit
(unlocked) 63-64
OFF (open) ON (closed) ON (closed) ON (closed) ON (closed)
Solenoid Power A1-A2
ON (energized) OFF (de-energized) OFF (de-energized)
ON (energized)
(Note 2)
OFF to ON
(Note 1) (Note 2)
Note 1: Do not attempt manual unlocking while the solenoid is energized.
Note 2: Do not energize the solenoid for a long period of time while the door is open or while the door is unlocked manually.
Operation Characteristics (reference)
• The operation characteristics show the contact status when the
actuator enters into the center of the entry slot.
• The circuit No. 12-41 and 22-51 are interconnected. Use circuits
11-42 and 21-52 for safety circuits (In HS1L-R model, circuit 12-41 is
interconnected.)
30.0
10.0
4.2 (Locked position)
0 (Actuator insertion position)
7.0
Door Monitor Circuit (Door closed,NC
)
Lock Monitor Circuit (Locked, NC)
Door Monitor Circuit (Door open, NO
)
Main Circuit
Lock Monitor Circuit (Unlocked, NO
)
Contacts ON (closed)
Contacts OFF (open)
(Approx. travel in mm)