Datasheet

4
HS5D Miniature Interlock Switches
Terminal Arrangement
Main Circuit: 11-12
Main Circuit: 21-22
Monitor Circuit: 31-32 / Monitor Circuit: 33-34
Accessories
Package Quantity: 1
Name Type No. (Ordering Type No.) Remarks
Plug Actuator HS9Z-A5P Can also be used for HS5B and HS5E
Door Handle
Actuator
Handle Unit
HS9Z-DH5RH Can also be used for HS5B and HS5E. For right-hand door.
HS9Z-DH5LH Can also be used for HS5B and HS5E. For left-hand door.
Switch Cover Unit HS9Z-DH5C
Used for installing the interlock switch inside.
Can also be used for HS5B and HS5E
HS5B/HS5D Installation Kit HS9Z-DH5B Used for mounting HS5B and HS5D
Sliding Actuator HS9Z-SH5 Can also be used for HS5B and HS5E
Padlock Hasp HS9Z-PH5 Can also be used for HS5B and HS5E
Actuator
Package Quantity: 1
Name Type No. (Ordering Type No.)
Straight HS9Z-A51
Straight w/rubber bushings HS9Z-A51A
Right-angle HS9Z-A52
Right-angle w/rubber bushings HS9Z-A52A
Angle Adjustable (vertical/horizontal) Type HS9Z-A55
Miniature Safety Interlock Switch
Package Quantity: 1
Contact Conguration Gland Port Size
Type No. (Ordering Type No.)
Plastic Head Type Metal Head Type
1NC-1NO
Main Circuit
Monitor Circuit
1211
23 24
Zb
G1/2 HS5D-11RN HS5D-11ZRN
PG13.5 HS5D-11RNP HS5D-11ZRNP
M20 HS5D-11RNM HS5D-11ZRNM
2NC
Main Circuit
Monitor Circuit
11 12
2221
Zb
G1/2 HS5D-02RN HS5D-02ZRN
PG13.5 HS5D-02RNP HS5D-02ZRNP
M20 HS5D-02RNM HS5D-02ZRNM
2NC-1NO
1211
21 22
33 34
Zb
Main Circuit
Main Circuit
Monitor Circuit
G1/2 HS5D-12RN HS5D-12ZRN
PG13.5 HS5D-12RNP HS5D-12ZRNP
M20 HS5D-12RNM HS5D-12ZRNM
3NC
11 12
21 22
3231
Zb
Main Circuit
Main Circuit
Monitor Circuit
G1/2 HS5D-03RN HS5D-03ZRN
PG13.5 HS5D-03RNP HS5D-03ZRNP
M20 HS5D-03RNM HS5D-03ZRNM
Contact Configuration and Operation Chart
Type Contact Conguration Contact Operation Chart (reference)
0 (Actuator Mounting Reference Position)
HS5D-11*
Main Circuit
11
12
11-12
23-24
Monitor Circuit
23
24
HS5D-02*
Main Circuit
11
12
11-12
21-22
Main Circuit
21
22
HS5D-12*
Main Circuit
11
12
11-12
21-22
33-34
Main Circuit
21
22
Monitor Circuit
33
34
HS5D-03*
Main Circuit
11
12
11-12
21-22
31-32
Main Circuit
21
22
Monitor Circuit
The operation characteristics shown in the chart above are for the HS9Z-A51.
For other actuator types, add 1.3 mm.
The operation characteristics show the contact status when the actuator enters the
entry slot of an interlock switch.
: Contact ON
(closed)
: Contact OFF
(open)
Actuator inserted
completely
Actuator removed
completely
Approx.
4.6
Approx.
6.7
Approx. 26.4
(Travel: mm)
31
32
(100405)