User guide

115
2 Mitsubishi
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Connection to a PLC
External Device Setup Manual
Word Device
Device Name Device Symbol Address Range Read
/Write
Address
Gradual
MICRO/I PLC
Special Register SD SD 000000 - 002047 R dec
Data Register D D 000000 - 029695 R/W dec
Link Register W W 000000 - 0073FF R/W hex
Timer (current value) TN TN 000000 - 029695 R dec
Retentive Timer (current value) SN SN 000000 - 029695 R/W dec
Counter (current value) CN CN 000000 - 029695 R dec
Special Link Register SW SW 000000 - 0007FF R/W hex
File Register R R 000000 - 032767 R/W dec
Extend file Register ZR ZR 000000 - 0FE7FF R/W hex
Special Relay (word) WSM SM 000000 - 002032 R
dec
*1
*1. Set this device using a multiplier of 16.
Input Relay (word) WX X 000000 - 001FF0 R
hex
*1
Output Relay (word) WY Y 000000 - 001FF0 R/W
hex
*1
Internal Relay (word) WM M 000000 - 475120 R/W
dec
*1
Latch Relay (word) WL L 000000 - 475120 R/W
dec
*1
Annunciator (word) WF F 000000 - 475120 R/W
dec
*1
Edge Relay (word) WV V 000000 - 475120 R/W
dec
*1
Link Relay (word) WB B 000000 - 073FF0 R/W
hex
*1
Link Special Relay (word) WSB SB 000000 - 0007F0 R/W
hex
*1
Step Relay (word) WS S 000000 - 008176 R/W
dec
*1