User guide

111
2 Mitsubishi
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Connection to a PLC
External Device Setup Manual
2.5.9 MELSEC-FX (CPU)
Bit Device
Device Name Device Symbol Address Range Read
/Write
Address
Gradual
MICRO/I PLC
Input Relay X X 0 - 337 R
*1
*1. Set this device using octal.
Output Relay Y Y 0 - 337 R/W
*1
Internal Relay M M 0 - 1535 R/W
Timer (contact) TS T 0 - 255 R
Counter (contact) CS C 0 - 255 R
State SS0 - 999 R/W
Word Device
Device Name Device Symbol Address Range Read
/Write
Address
Gradual
MICRO/I PLC
Input Relay WX X 0 - 320 R
*1
*2
*1. Set this device using octal.
*2. Set this device using a multiplier of 16.
Output Relay WY Y 0 - 320 R/W
*1
*2
Internal Relay WM M 0 - 1520 R/W
*2
Timer (current value) TN T 0 - 255 R
Counter (current value) CN C 0 - 199 R
32-Bit Counter (current value) DCN C 2000 - 2551 R
*3
*3. This device is a 32-bit device.
Data Register D D 0 - 999 R/W
State WSWS0 - 976 R/W