3 Data Log Settings Dialog Box
14-16 WindO/I-NV2 User’s Manual
3.2 Individual Settings Dialog Box
Use the Individual Settings dialog box to register or edit the Data Log settings for the selected channel.
General Tab
The General tab is used to configure the source devices for sampling data and the sampling conditions.
Channel No.
Specifies the channel number for sampling data (1 to 20).
Log function
Selects whether or not to use the Data Log function.
Data Size
*1
Selects the data size of the source device as 16-bit or 32-bit.
The value of device in the selected data size is read and saved in the data storage area.
Source
Specifies the word device that is the source for sampling data.
For the device address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
*1 HG2G-5F, HG3G/4G only
Enable: Samples values of devices and saves the data along with the sampling time.
Disable: Does not sample values of devices.