WindO/I-NV2 User’s Manual 11-25
2 Line Chart
11
Charts
Scroll Size
Specifies the number of points of data to scroll when updating the chart display (1 to the value of Display Points).
This option can only be configured when Log Trend (Normal) is selected for Chart Type.
Example: When Display Points is 5 and Scroll Size is 3
Restart Chart
Select this check box to display the chart from the beginning when switching screens.
This option can only be configured when Log Trend (Normal) or Log Trend (Pen Recorder) is selected for Chart
Type.
*2 HG2G-S/-5S/-5F, HG3G/4G only
(Data Type)
*2
: Selects the data type to use with the scroll size.
Value:
Device:
Uses a constant.
Uses a word device.
(Scroll size): Specifies the number of points of data to scroll (1 to the value of Display Points). The handled
data type is BIN16(+) only.
When Device is selected for (Data Type)
*2
, the scroll size can be specified in the word device.
Click to display the Device Address Settings dialog box. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
The minimum value of Scroll Size is 1. If the value of device is smaller than the minimum value, then
Scroll Size remains at 1. If the value is larger than Display Points, then Scroll Size is the value of
Display Points.
0
20
40
60
80
100
-20
120
0
20
40
60
80
100
-20
120
0
20
40
60
80
100
-20
120
2. Shi data 3 points le1. Reached maximum amount
of data to display
3. Display next data
MICRO/I MICRO/I MICRO/I
1234
0
20
40
60
80
100
-20
0
20
40
60
80
100
-20
Switch screen Switch screen
Base screen 1 Base screen 1Base screen 2
Display chart
from beginning