Manual
1 Numerical Input
10-16 WindO/I-NV2 User’s Manual
Trigger Type: Selects the condition to display the Numerical Input from the following.
Always visible: The Numerical Input is always displayed.
While ON: Displays the Numerical Input when the value of device is 1.
While OFF: Displays the Numerical Input when the value of device is 0.
While satisfying the condition:
Displays the Numerical Input when the condition is satisfied.
Data Type: Selects the type of data handled by the conditional expression for the visible condition.
This option can only be configured if While satisfying the condition is selected for Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.
Device: Specifies the bit device or bit of the word device to serve as the visible condition.
This option can only be configured when While ON or While OFF is selected for Trigger Type.
Click to display the Device Address Settings dialog box. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
Condition: Specifies the conditional expression for the visible condition.
This option can only be configured when While satisfying the condition is selected for Trigger
Type.
Click to display the Trigger Condition Settings dialog box. For the conditional expression
configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.
Comment: Used for entering a comment for the visible condition. The maximum number is 80 characters.
Always show
Numerical
Input state
123
1
0
Hide
Show
Hide Hide
Show Show
Value of Device
Numerical
Input state
123 123 123
Value of Device
1
0
Show Show ShowHide Hide Hide
Numerical
Input state
123 123 123
Numerical
Input state
Hide Hide Hide
Show Show Show
Satisfied
Not satisfied
Condition
123 123 123