Manual

WindO/I-NV2 User’s Manual 8-151
9 Potentiometer
8
Buttons
Trigger Condition Tab
The Trigger Condition tab is displayed in Advanced mode.
Input Condition
The Potentiometer is enabled and operational while the condition is satisfied. The Potentiometer is disabled and not
operational while the condition is not satisfied.
Example: When Trigger Type is While ON and Device is LM 0
While LM 0 is 0, the condition is not satisfied and the Potentiometer is not operational.
While LM 0 is 1, the condition is satisfied and the Potentiometer is operational.
Trigger Type: Selects the condition to enable the Potentiometer from the following.
Always enable: The Potentiometer is always enabled.
While ON: Enables the Potentiometer when the device value is 1.
LM0
:
MICRO/I
0
LM0
:
1
Button
Does not
operate
Button
Operates
Condition
Not
satisfied
Condition
Satisfied
Enabled
Potentiometer
state
1
0
Device value
Disabled Disabled DisabledEnabledEnabledEnabled
Potentiometer
state