4 HG2F
34-54 WindO/I-NV2 User’s Manual
4.7
Installation
Operating Environment
For designed performance and safety of the HG2F, do not install the HG2F in the following environments:
Where dust, briny air, or iron particles exist.
Where oil or chemical splashes for a long time.
Where oil mist is filled.
Where direct sunlight falls on the HG2F.
Where strong ultraviolet rays fall on the HG2F.
Where corrosive or combustible gasses exist.
Where the HG2F is subjected to shocks or vibrations.
Where condensation occurs due to rapid temperature change.
Where high-voltage or arc-generating equipment (electromagnetic contactors or circuit protectors) exists in the
vicinity.
Ambient Temperature
Allow sufficient space for ventilation, and install the equipment away from heat sources.
Allow at least 100mm between the HG2F and walls or other equipment.
Do not install the HG2F where the ambient temperature exceeds the rated operating ambient temperature range.
When mounting the HG2F in such locations, provide a forced air-cooling fan or air-conditioner to keep the ambient
temperature within the rated temperature range.
The HG2F is designed to install on a vertical plane so that natural air-cooling is provided. If you install it using any
other orientation, use forced-air cooling, or lower the ambient operating temperature.
HG2F Installation
Make a panel cut-out on the panel with the dimensions shown below.
Place the HG2F in a panel cut-out and fasten with the attached mounting clips at four places to a torque of 0.15 to
0.2 N•m uniformly.
CAUTION
• Do not tighten excessively, otherwise the HG2F may warp and cause wrinkle on the display, or
impair the waterproof characteristics.
• If the mounting clips are tightened obliquely to the panel, the HG2F may fall off the panel.
When installing the HG2F into a panel cut-out, make sure that the gasket is not twisted. Especially
when re-installing, take special care because any twists in the gasket will impair the waterproof
characteristics.
B
A
Panel
Mounting
Clip
HG2F