Manual
WindO/I-NV2 User’s Manual 34-39
3 HG1F
34
MICRO/I Specifications
3.5 Specifications
■ Applicable Standards
■ Environmental Specifications
■ Electrical Specifications
■ Construction Specifications
Safety Standard
UL508, ANSI/ISA 12.12.01,
CSA C22.2 No.213
EMC Standard IEC/EN 61000-6-4, IEC/EN 61131-2:2007
Operating Ambient Temperature 0 to 50°C
Operating Relative Humidity 10 to 90% RH (no condensation)
Storage Ambient Temperature -20 to +60°C
Storage Relative Humidity 10 to 90% RH (no condensation)
Altitude (Operation) 0 to 2000m
Pollution Degree 2
Corrosion Immunity Free from corrosive gases
Rated Operating Voltage 24V DC
Power Consumption 10W maximum
Power Voltage Range 20.4V DC to 28.8V DC
Allowable Momentary Power
Interruption
10 ms maximum
Inrush Current 20A maximum
Dielectric Strength AC1000V, 10mA, 1 minute (between power and earth terminals)
Insulation Resistance 50 MΩ minimum (500V DC megger) (between power and earth terminals)
Vibration Resistance
10 to 20 Hz, amplitude 0.625mm
20 to 55 Hz, 9.8 m/s
2
[2 hours each in 3 axes] (IEC60068-2-6)
Shock Resistance
147 m/s
2
, 11 ms