Owner manual
LOGIC 
5-33 
Chapter 5 
Unused safety inputs  Terminal names  Connection 
X0-T0 Open Safety input 1 
X1-T1 Short 
X2-T2 Open Safety input 2 
X3-T3 Short 
X4-T4 Open Safety input 3 
X5-T5 Short 
X6-T6 Open Safety input 4 
X7-T7 Short 
X10-T10 Short Safety input 5 
X11-T11 Short 
X12-T12 Short Safety input 6 
X13-T13 Short 
●External device monitor inputs: X14 and X15 (T14 and T15) 
External device monitor inputs are used to diagnose the status of devices connected to safety outputs. 
Intended inputs 
(Terminal names) 
Target safety 
outputs 
(Terminal 
names) 
Function 
External device monitor input 1 
(X14-T14) 
Safety output 1
(Y0, Y1) 
Function name  External device monitor input 
External device monitor input 2 
(X15-T15) 
Safety output 2
(Y2, Y3) 
Symbol 
External Device
Monitor
EDM
 Description of 
operation 
This function diagnoses the 
status of devices connected to a 
target safety output. 
 Detail information Logic functions (5-326) 
Warning
Safety check signals (pulses signals) are sent from the drive terminals (T14, T15) to diagnose external 
devices and monitor circuits. Safety check signals can not be used as a power supply for connected 
devices. 
Note. If there are unused safety outputs, connect the intended external device monitor terminals (Xn) 
to the corresponding drive terminals (Tn). If they are not connected, the SafetyOne detects an 
input monitor error. As the result, the error LED displays a “1” and the unit changes to the 
Protection state. 