Owner manual

LOGIC
5-272
Logic 106: Partial stop logic for apparatus with openings
Overview (Logic 106)
This logic is for using safety devices with dual channel solid state outputs, such as safety light
curtains, for safety protective measures of production machinery and robots. Safety outputs
perform as single channel outputs.
This logic enables the connection of 5 dual channel safety inputs.
Safety input 1
Safety input 2
Safety input 3
Safety output 1
Safety input 4
Safety input 5
Safety output 2
System runs
System runsSystem runs
System runs System runs
Safety output 3Safety output 4
Logic 106
Emergency
stop switch
Safety light
curtain
(PNP type)
Safety
output 1
Safety
output 2
Safety
output 4
Safety
output 3
Operation example (Logic 106)
System stops
Safety input 1
Safety input 2
Safety input 3
Safety input 4
Safety input 5
Safety output 1
Safety output 2Safety output 3Safety output 4
System runsSystem runs
System runs
blocked!
Beams
System stops System stops
System stops
System runs
Safety output 1
Safety output 2
Safety output 3Safety output 4
Safety input 1
Safety input 2
Safety input 3
Safety input 4Safety input 5
blocked!
Beams
Press!
System stops System stops
System stops
System stops
Safety input 1
Safety input 2
Safety input 3
Safety input 4Safety input 5
Safety output 1
Safety output 2
Safety output 3
Safety output 4