Owner manual

LOGIC
5-211
Chapter 5
Logic circuit (Logic 14A)
Safety input 1
T0, X0, X1
Teach mode
Auto mode
Y0
Y1
Y2
Y3
T2, X2, T3, X3
Safety input 2
T4, X4, T5, X5
T6, X6, T7, X7
T10, X10, T11, X11
T14, X14
T15, X15
X16
X1 7
Safety input 5
Safety input 4
Safety input 3
Start input 1
Start input 2
External device
monitor 4
External device
monitor 3
Contorl
Start
Control
T12, X12
T13, X13
External device
monitor 2
External device
monitor 1
>=1
Safety output
1-1
Safety output
2-1
Safety output
1-2
Safety output
2-2
OS1
OS2
&
Mode
Select
&
&
&
Single Channel
Monitor
Single Channel
Monitor
Dual Channel
Direct Opening
Dual Channel
Direct Opening
Dual Channel
Direct Opening
Dual Channel
Dependent
External Device
Monitor
EDM
External Device
Monitor
EDM
External Device
Monitor
EDM
External Device
Monitor
EDM
Hold
Trigger
Self-hold
function
Self-hold
function circuit 3
Hold
Trigger
Self-hold
function
Self-hold function circuit 2
Hold
Trigger
Self-hold
function
Self-hold function circuit 1
Hold
EDM
OSSD
Hold
EDM
OSSD
Hold
EDM
OSSD
with
Off delay
Hold
EDM
OSSD
with
Off delay
Monitor output for safety input Monitor output for safety output
(Note1)
X0
Y4
Safety inptut 1
monitor
X3
X2
Y5
X5
X4
Y6
X7
X6
Y7
X11
X10
Y10
Safety input 2
monitor
Safety input 3
monitor
Safety input 4
monitor
Safety ilnput 5
monitor
&
&
&
&
OS1
Y12
Y13
Y0
Y1
Safety output 1-1
monitor
Safety output 1-2
monitor
(Note2)
&
OS2
Y17
Y20
Y2
Y3
&
Safety output 2-1
monitor
Safety output 2-2
monitor
(Note2)
Note2:
Safety output 1-2 and safety output 2-2 turn
OFF immediately independent of OFF-delay
time.
Note1:
When safety input 1 is set to Auto
mode, safety input 1 monitor turns
OFF.