User Manual

IDEC SmartRelay installation and wiring
40 IDEC SmartRelay Manual
Input Internal Circuit
FL1E-H12RCC / FL1E-B12RCC
FL1B-M08C2R2
I1~I8
N
100nF
390kΩ 180kΩ 270kΩ
47kΩ
Internal Circuit
Digital AC/DC Input
AC
2-wire
Sensor
I1 to I8
R4
100 to 240 V AC
N
L1
When using the AC two-wire sensor
I1~I8
N
100nF
390kΩ 390kΩ
62kΩ
Internal Circuit
270kΩ
Digital AC/DC Input