8.5.1 Requirements for a gate control system
Every gate is opened and closed by means of a
cord-operated switch. The gate is will be fully opened or
fully closed.
All gate can be opened and closed locally by means of
pushbuttons.
The gate can be opened and closed at the gatehouse by
means of the bus system. The GATE OPEN or GATE
CLOSED status is indicated.
An indicator lamp is switched on five seconds before the
gate starts moving and when the gate is in motion.
A safety pressure bar prevents harm to persons and
objects from getting trapped or damaged when the gate
closes.
Wiring of the gate control system with FL1E-H12RCC and CM AS-
Interface
N
L1 N I3 I4 I5 I6 I7 I8
K1
K2
L1
S0 S1 S2 S3 S4 S5
S6
p
>
S6
p
>
I2I1
Q1 Q2 Q3 Q4
1 2 1 2 1 2 1 2
Gate Gate Indicator lamp
AS-Interface