Datasheet
Precautions & Instructions
800.262.4332
www.IDEC.com/switches
Operating Instructions con’t
Pushbuttons
Pushbutton caps cannot be removed. Do not 
tamper with the cap using a screwdriver or 
pliers, otherwise it may be damaged.
Selector Switches
Turn the selector operator or key to the detent 
positions.
Key Selector Switches
To prevent malfunction and damage, take the 
following precautions.
•Completely insert the key before turning.
•Do not remove the key while turning.
•Besides the standard key (0H), six other keys 
are available. Use only a key with a number 
that matches the number on the switches’ 
key cylinder. (The standard key does not have 
a key number.)
•Keys are available in two shapes. 
-0H (standard), 1H, 2H: reversible keys 
-3H, 4H, 5H, 6H: non-reversible keys 
Make sure of correct insertion direction.
Contact Blocks and LED Modules
To remove the contact block from the operator, 
insert a flat screwdriver under the latch and 
push the screwdriver down as shown below. 
Before removing the LED module, first remove 
all contact blocks, and then remove the LED 
module in the same manner.
Wiring
Applicable Wires
Stranded wire: 2.0 mm
2
 maximum (14AWG) 
Solid wire: ø1.6 mm maximum
8.0 max.
ø1.6 max.
One or two wires can be connected to the 
terminal.
Applicable Crimping Terminals
Spade terminal
When using crimping terminals, be sure to use 
insulating tubes or insulated crimping termi-
nals.
11.5 max.
8.1 max.
6.9 max.
3.6 min.
0.5 min.
Crimping Terminal
Wire
Insulation Tube
Ferrule
When connecting two ferrules to one terminal, 
use ferrules without insulation.
8.0 max.
1.7 max.
Insulation
8.0 max.
1.7 max.
When using spade terminals or ferrules, 
ensure that they are inserted completely. 
Ring terminals cannot be used.
Screw Tightening Torque
Tighten the M3.5 terminal screws to a recom-
mended torque of 1.0 to 1.3 N·m.
23