Datasheet
Stop Switches
ø16mm XA series Stop Switch Pushlock Pull or Turn Reset with Removable Contact Block Package quantity: 1
Description & Shape
NC Main
Contact
NO Monitor
Contact
Part No.
Solder Terminal PCB Terminal
ø29mm Mushroom
1NC —
XA1E-BV301
➀
XA1E-BV301V
➀
2NC —
XA1E-BV302
➀
XA1E-BV302V
➀
3NC —
XA1E-BV303
➀
XA1E-BV303V
➀
4NC —
XA1E-BV304
➀
XA1E-BV304V
➀
1NC 1NO
XA1E-BV311
➀
XA1E-BV311V
➀
2NC 1NO
XA1E-BV312
➀
XA1E-BV312V
➀
3NC 1NO
XA1E-BV313
➀
XA1E-BV313V
➀
ø40mm Mushroom
1NC —
XA1E-BV401Y XA1E-BV401VY
2NC —
XA1E-BV402Y XA1E-BV402VY
3NC —
XA1E-BV403Y XA1E-BV403VY
4NC —
XA1E-BV404Y XA1E-BV404VY
1NC 1NO
XA1E-BV411Y XA1E-BV411VY
2NC 1NO
XA1E-BV412Y XA1E-BV412VY
3NC 1NO
XA1E-BV413Y XA1E-BV413VY
• Specify button color code Y (yellow) or N (gray) in place of
➀
in the Part No.
• Pushlock pull or turn reset is locked when pressed, and reset when pulled or turned clockwise.
• Terminal cover (XA9Z-VL2) is not supplied and must be ordered separately.
• See page 15 for specifications and instructions.
ø16mm X6 series Stop Switch Pushlock Pull or Turn Reset Unibody (Solder Terminal) Package quantity: 1
Description & Shape Operator NC Main Contact Part No.
(Photo: ø30mm Mushroom)
ø30mm
1NC
AB6E-3BV01PY
2NC
AB6E-3BV02PY
ø40mm
1NC
AB6E-4BV01PY
2NC
AB6E-4BV02PY
• Pushlock pull or turn reset is locked when pressed, and reset when pulled or turned clockwise.
• Do not use yellow stop switches as emergency stop switches.
• See page 8 for specifications and instructions.
ø16mm XA series Stop Switch Pushlock Pull or Turn Reset Unibody (Solder Terminal) Package quantity: 1
Description & Shape Operator
NC Main
Terminal
Part No.
IP40 IP65
(Photo: ø29mm Mushroom)
ø29mm
1NC
XA1E-BV3U01K
➀
XA1E-BV3U01
➀
2NC
XA1E-BV3U02K
➀
XA1E-BV3U02
➀
ø40mm
1NC
XA1E-BV4U01K
➀
XA1E-BV4U01
➀
2NC
XA1E-BV4U02K
➀
XA1E-BV4U02
➀
• Specify button color code Y (yellow) or N (gray) in place of
➀
in the Part No.
• Pushlock pull or turn reset is locked when pressed, and reset when pulled or turned clockwise.
• Solder/tab 110 terminal is available. To order, insert ”T” before the Y in the Part No. Example: XA1E-BV3U02KYXA1E-BV3U02KTY
• See page 13 for specifications and instructions.
Stop Switches
Wider variety with yellow button, white guard and nameplate
According to SEMI S26-0308 Environmental, Health, and Safety Guideline for FPD Manufacturing Systems published in
March 2008, the combination of a red button and yellow background cannot be used for switches that have only local or
partial shut down functions. IDEC’s yellow button switch, white switch guard, and nameplate can satisfy the requirement.
www.apem-idec.eu
D-076