c. Make electrical plug wiring connection for the Electro-Matic Release Valve, by locating the Plug C from
Wiring Harness and matching Plug C connector from the power units Electro-Matic Release Valves
wiring harness, as shown below in Fig. 7. NOTE: Ensure plug connectors are securely locked
together.
d. Using the Wiring Harness from Frame Lift & Wiring Harness from Control Panel, make electrical plug
connections for the Electro-Matic Lift Latches, by locating the Plugs E from both wiring harnesses.
Connect together, as shown below in Fig.7. NOTE: Ensure both plug connectors are securely locked
together.
e. Using the Wiring Harness from Frame Lift and the 90 degree Fitting for Power Unit, make Hydraulic Hose
connection to Power Unit. Secure hydraulic hose to 90 degree fitting, shown below in Fig.7.
NOTE: Ensure hydraulic fitting connections are properly tightened together but DO NOT
overtighten.
Fig.7
5. Main Power Connection
Before power connection is made, check power supply outlet to ensure it is in accordance with the
requirements of the lift.
a. Connect lifts electrical plug to an 110V-60Hz, 1Ph, 20A power
supply outlet (Fig.8).
Protection against power surges shall be provided by the
user.
NOTE: If using an extension cord, ensure to use
extension cord rated for 20 amps.
Fig.8