Installation Guide

12
TP12KSC-DX
July 2018-A
FOUNDATION and ANCHORING REQUIREMENTS
Drill holes using 3/4” Clean hole. Run nut down just Tighten nut with
carbide tipped
below impact section Torque wrench to
masonry drill bit per
of bolt. Drive anchor 110 ft.-lbs.
ANSI standard
into hole until nut and
B94.12.1977
washer contact base.
2.3 Tools & Equipment Required
12 quarts of Non-Detergent / Non-Foaming Hydraulic Oil - SAE-10, AW 32 or equivalent
Chalk line and 12’ Tape Measure
Concrete hammer drill with 3/4” bit
11/16” open end wrench
3/4” open end wrench
Torque wrench
15/16” deep socket or wrench
1-1/8” socket
13/16” open end wrench
Level (18” minimum length)
Vise grips
Tape measure
Funnel
Hoist or Forklift (optional)
Two 12’ step ladders
1/4” drive ratchet with 5/16” socket
3-1/2”
3-1/2”
4-1/2”
4-1/2”