Instructions / Assembly

iDEAL Paint Spray Booth (PSB-SDD26B-AK)
29
4.15 PRODUCT DOOR LIMIT SWITCH & LATCH INSTALLATION
1. Attach limit switch to limit switch mounting plate (may be mounted on right or left plate) so actuating arm aligns
with door edge.
2. Adjust actuating arm so trigger plate will actuate switch.
3. Attach trigger plate to door edge so it actuates switch.
4. Make final adjustments to lever arm to assure proper operation and tighten set screw on limit switch lever arm.
5. Attach striker to top edge of door so it will actuate roller in latch.
6. Attach latch to plate so it is actuated by striker.
7. Repeat 5 and 6 on center door plate
4.16 LIMIT SWITCH WIRING
1. Obtain line power from proper terminal in remote Control Panel and wire it to the first Limit Switch (Local Codes
may require Limit Switches to be wired using rigid sealed off conduit).
2. Run line power from the first Switch to the second Switch.
3. Continue wiring all Switches in this manner to be in series.
4. Return the last line wire to the remote Control Panel and connect it to the proper terminal.
5. Controller in remote Control panel will now control the Air Solenoid in spray mode and Heat system in Bake
mode (manual override must be reset if tripped) when door (s) are open.
Door Latch Assy
Door Latch Assy
Limit
Switch
Door Striker
Bracket
Door Frame
Tri-Fold Doors