User Guide
To measure Kilowatts and Power Factor in a single
phase 2-wire system
• Set rotary switch to PF/kW without jaws clamping onto any
wire
• If the watt reading is not zero, press the DC A/W ZERO
button once to zero out the watt reading.
• Insert the black test lead into the COM terminal and the red
test lead into the + terminal.
• Connect the black test probe to the neutral conductor and
the red test probe to the hot conductor.
• Using the trigger to open the jaws, fully enclose the hot
conductor within the clamp.
• Release the trigger and be sure that the jaws have closed
completely.
• The power clamp selects the appropriate range based on the
Autoranging table.
• Power Factor (PF) is a calculated value based on the
formula
PF=_______
• The kW value is shown on the main display and the PF
value is shown on the upper display.
• Positive PF (+) indicates an inductive load, while negative
PF (-) indicates a capacitive load.
8
To measure Kilowatts and Power Factor in a single
phase 3-wire system
See section on 1
φ
3W AC+DC Power Measurements
AC+DC Voltage/Frequency Measurements
Voltage Resolution Accuracy Accuracy Input
Range (50/60Hz) (40-400Hz) Impedance
0-200V 0.1V ±(1.5% +5) ±(2.0% +5) 10M
200-500V
500-600VAC 1V
500-800VDC
Overload Protection: 800V
TRMS Measurements
Accuracies specified at Crest Factor <3.5
Frequency Range Accuracy Sensitivity
50/60Hz ±(0.5% + 2) >5V
10-400Hz
To Measure Voltage and Frequency
• Set the rotary switch to V/Hz
• Insert the black test lead into the COM terminal and the red
test lead into the + terminal.
• Connect the test probes in parallel with the load or circuit.
• The power clamps automatically selects the proper range.
Note: The “+” sign on the jaw must face the power source for
correct measurement.
kW
kVA
3ØPF
AC+DC
2000KW
2000A
OFF
PFKW
HzV
3Ø3W
3Ø4W
KVARKVA
VA
D
C
A
/
W
Z
E
R
O
R
E
C
3
Ø
K
V
A
R
K
V
A
R
E
A
D
NEX
T
HOLD
CAT III - 600V
P
o
w
e
r
C
l
a
m
p
True
R
M
S
6
1
-
8
0
2
7