User Guide

5
3
φ
KVAR KVA Button
The 3
φ
KVAR KVA button toggles between the KVAR/KVA
measurements and the PF/kW measurements in the 3
φ
3W
or 3
φ
4W functions.
Toggling between these measurements can only be done
after the power clamp has calculated the power factor and
kW measurement.
Read Next Button
In 3
φ
3W Function
Pressing the read next button stores the measured values
for kW
RS(L1L2)
/kVA
RS(L1L2)
and moves to the next measurement.
Pressing read next after the kW
TS(L2L3)
/kVAR
TS(L2L3)
stores the
values and calculates the kW and PF values for the 3
φ
3W
system.
After these values have been calculated, press the 3
φ
KVAR
KVA button to display the KVAR and KVA values for the sys-
tem.
To start another calculation, press the read next button again
to return and take a measurement for the kW
RS(L1L2)
/kVARS
(L1L2)
values.
In 3
φ
4W Function
Pressing the read next button stores the measured values
for W
R(L1)
/PF
R(L1)
and moves to the next measurement.
Pressing read next after the W
S(L2)
/PF
S(L2)
stores the values
and moves on to the next measurement.
Pressing read next after the W
T(L3)
/PF
T(L3)
stores the values
and calculates the kW and PF values for the 3
φ
4W system.
After these values have been calculated, press the 3
φ
KVAR
KVA button to display the KVAR and KVA values for the sys-
tem.
To start another calculation, press the read next button again
to return and take a measurement for the W
R(L1)
/PF
R(L1)
values.
6
In any other function
Pressing the read next button in any other function displays
the measurement values stored with the REC button.
The REC NO. symbol will be shown on the LCD display and
the record number will flash on the secondary display to noti-
fy the user of what values are being displayed.
Pressing this button after the meter displays last stored data
point returns to the first stored data point.
To exit the read next mode, turn the function switch to any
other function. This will exit without losing the stored data.
Kilowatt/Power Factor Measurements
Kilowatt Range Resolution Accuracy Voltage/Current
(AC+DC True Power) Range
0-99.99kW 0.01kW ±(2.0% +0.05) 600VAC, 800VDC
100-999.9kW 0.1kW 2000A AC/DC
1000-1600kW 1kW ±(2.0% +5)
Power Factor 0.2-1.0 for 1
φ
2W, 1
φ
3W, 3
φ
3W, and 3
φ
4W
Autoranging Table 0-200VAC 200-600VAC
0-200VDC 200-800VDC
0-200A 0.00-40.00kW 0.00-99.99kW
100.0-160.0kW
200-2000A 0.0-400.0kW 0.0-999.9kW
1000-1600kW
3ØP
F
A
C
+
D
C
2
0
0
0
K
W
2
0
0
0
A
OF
F
P
F
K
W
H
z
V
3Ø3W
3Ø4W
KVARKVA
VA
D
C
A
/
W
Z
E
R
O
R
E
C
3
Ø
K
V
A
R
K
V
A
R
E
A
D
NEX
T
HOLD
C
A
T
I
I
I
-
6
0
0
V
Power Clamp
True RMS
61-802