User Guide
8
DC Volts
Range Resolution Max Display Accuracy
400mV 0.1mV 400.0 +
(1.5% +8)
400mV 100µV 400.0 +(0.3% +2)
4V 1mV 4.000 +
(0.1% +2)
40V 10mV 40.00
400V 100mV 400.0
1000V 1V 1000
To Measure DC Voltage:
1. Plug the Black test lead into the COM port and the Red
test lead into the Ω port.
2. Set the rotary switch to the V position.
3. Push the blue button until DC is shown on the display.
4. Connect the meter in parallel with the load or circuit.
5. Measure DC Voltage
Input Impedance: 10MΩ (over 1000MΩ in 400mV range)
MIN/MAX
~Hz PEAK
HOLD
Data Acquisition
2
Circuit Connection:
7
AC Volts
Range Resolution Max Display Accuracy
400mV 0.1mV 400.0 +
(1.5% +8)
40Hz ~ 60Hz
4V 1mV 4.000 +(1.0% +5)
40Hz ~ 500Hz
40V 10mV 40.00 +(0.5% +5)
50Hz ~ 60Hz
+(1.0% +5)
40Hz ~ 1kHz
400V 100mV 400.0
750V 1V 750
To Measure AC Voltage:
1. The Plug the Black test lead into the COM port and the
Red test lead into the VΩHz port.
2. Set the rotary switch to the V position.
3. Push the blue button until AC is shown on the display.
4. Connect the meter in parallel with the load or circuit.
5. Measure AC Voltage
Input Impedance: 10MΩ less than 100PF
MIN/MAX
~Hz PEAK
HOLD
Data Acquisition
2
Circuit Connection: