#61-482 480 Platinum Pro Series Commercial Contractor Grade Multimeter Symbols in this Manual This symbol indicates where cautionary or other information is found in the manual. Fuse Battery Refer to Figure 1 and to the following numbered steps to familiarize yourself with the meter’s front panel controls and connectors.
1. Digital Display – The digital display has 4000 counts LCD readout with 82 segments analog bar graph, auto polarity, decimal point, “ ” AC, DC RANGE, H APO and unit annunciators. 2. Rotary Switch – Select the Function and Range desired. 3. COM Input Terminal – Ground input connector. 4. °C °F VΩHz Input Terminal – Positive input connector for Volts, Ohms Frequency, and Temperature. 5. mA Input Terminal – Positive input connector for Amp measurements (up to 400mA). 6.
Overload Protection Function VAC & VDC AAC & ADC Ohms (Ω) Diode Continuity True RMS AC Volt Circuit Connection: Overload Protection 1000V 1A/500V 16A/500V 600VAC/600VDC 600VAC/600VDC 600VAC/600VDC Unit of Measure Multipliers For your reference, the following symbols are often used to make measurement easier: Symbol Verbal Multiplier M mega x 1,000,000 k kilo x 1,000 m milli ÷ 1,000 µ micro ÷ 1,000,000 Auto Power Off (APO) The APO sign on the LCD panel indicates the meter is working in the Auto Power Off
True RMS AC Current DC Volts Circuit Connection: True RMS Range 400mV 4V 40V 400V 1000V Circuit Connection: True RMS Resolution 100µV 1mV 10mV 100mV 1V Max Display Accuracy 400.0 ±(0.25% +5) 4.000 ±(0.4% +1) 40.00 ±(0.25% +1) 400.0 1000 Input Impedance: 10MΩ (over 1000MΩ in 400mV range) To Measure DC Voltage: 1. Plug the black test lead into the COM port and the red test lead into the °C°F VΩHz port. 2. Set the rotary switch to the V position. 3.
Frequency/RPM DC Current Circuit Connection: True RMS True RMS Range 40mA 400mA 10A Circuit Connection: Resolution 10µA 0.1mA 10mA Max Display 40.00 400.0 10.00 Accuracy Voltage Burden ±(0.6% +2) 200mVmax ±(0.7% +2) 2Vmax ±(1.0% +3) 2V max Range Resolution Sensitivity 4.0KHz/40KRPM 1Hz/30RPM 100mV rms* 40KHz/400KRPM 10Hz/300RPM Accuracy Frequency: 0.01% ±1 digit 400KHz/4MRPM 100Hz/3KRPM 4MHz/40MRPM 1KHz/30KRPM 250mV rms RPM: 40MHz/400MRPM 10KHz/300KRPM IV rms 0.
Resistance (Ohms) Circuit Connection: True RMS Range 400Ω 4kΩ 40kΩ 400kΩ 4MΩ 40MΩ Resolution 0.1Ω 1Ω 10Ω 100Ω 1kΩ 10kΩ MaxDisplay 400.0 4.000 40.00 400.0 4.000 40.00 Accuracy ±(0.7% +3) ±(0.4% +3) Range Guide for Ohms (Ω): 400 = Meter indicates actual resistance 4k = Multiply meter display reading by 1,000 to acquire actual resistance. 40k = Multiply meter display reading by 1,000 to acquire actual resistance. 400k = Multiply meter display reading by 1,000 to acquire actual resistance.
Resistor Color Code Table 1st Color Digit Black 0 Brown 1 Red 2 Orange 3 Yellow 4 Green 5 Blue 6 Violet 7 Gray 8 White 9 Gold Silver No Color Temperature 2nd Tolerance Digit Multiplier (Percentage) 0 1 1 10 2 100 3 1,000 4 10,000 5 100,000 6 1,000,000 7 10,000,000 8 100,000,000 9 1,000,000,000 +/- 5% +/- 10% +/- 20% True RMS Example: Gold Yellow Red Blue 1st color band is blue so the first digit is a 6 2nd color band is red so the second digit is a 2 3rd color band is yellow so multiply 62 x 10,000
Diode Testing Capacitance Circuit Connection: True RMS True RMS Function Resolution Accuracy Max.Test Max.Open Current Circuit Voltage 1mV +(1.5% +5)* 1.5mA 3V * For 0.4V to 0.8V. Overload Protection: 600V rms max Diode Check: To ensure a proper functioning diode, the meter will develop a voltage across the component from a test current. The diode test function allows measurements of forward voltage drops across diode and transistor junctions. 1.
Continuity Check Peak Hold Measurements Circuit Connection: True RMS True RMS Function Range Accuracy Function Range Accuracy DC Voltage 400mV Unspecified AC Voltage 400mV Unspecified To Verify Continuity: A continuity test ensures that all circuit connections are intact. 1. Plug the black test lead into the COM port and the red test lead into the °C°F VΩHz port. 2. Set the rotary switch to the Ω position. 3. Press the blue button until is shown in the display. 4.
Accessories General Specifications LCD Display: Bar Graph Display: Polarity Indication: True RMS For AC Current Clamp (61-450): 1. Plug the black test lead into the COM port and the red test lead into the VΩHz port. 2. Remove the probe tips from the end of the leads. 3. Attach the leads to the current clamp. (polarity will not effect reading) 4. Set the rotary switch to the V position. 5. Push the blue button until AC ˜ is shown on the display. 6.
Maintenance Warning To avoid electrical shock, remove test lead before opening the cover. Repairs or servicing not covered in this manual should only be performed by qualified personnel. Battery Installation or Replacement: The #61-480 is powered by one 9V battery. 1. Remove the test leads from the front terminals and turn the meter off. 2. Remove the screw from the battery cover and lift to remove. 3. Replace battery. 4.
Lifetime Limited Warranty This meter is warranted to the original purchaser against defects in material or workmanship for the lifetime of the meter. During this warranty period, IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument.