#61-481 480 Platinum Pro Series Commercial Contractor Grade Multimeter Symbols in this Manual This symbol indicates where cautionary or other information is found in the manual. Fuse Battery Refer to Figure 1 and to the following numbered steps to familiarize yourself with the meter’s front panel controls and connectors.
1. Digital Display – The digital display has 4000 counts LCD readout with 82 segments analog bar graph, auto polarity, decimal point, “ ” AC, DC RANGE, H APO and unit annunciators. 2. Rotary Switch – Select the Function and Range desired. 3. COM Input Terminal – Ground input connector. 4. VΩHz Input Terminal – Positive input connector for Volts, Ohms and Frequency. 5. mA Input Terminal – Positive input connector for Amp measurements (up to 400mA). 6.
True RMS AC Volt Overload Protection Function VAC & VDC AAC & ADC Ohms (Ω) Diode Continuity Circuit Connection: Overload Protection 1000V 1A/500V 16A/500V 600VAC/600VDC 600VAC/600VDC 600VAC/600VDC Unit of Measure Multipliers For your reference, the following symbols are often used to make measurement easier: Verbal Multiplier Symbol M mega x 1,000,000 k kilo x 1,000 m milli ÷ 1,000 µ micro ÷ 1,000,000 Auto Power Off (APO) The APO sign on the LCD panel indicates the meter is working in the Auto Power Off
DC Volts True RMS AC Current Circuit Connection: Circuit Connection: Hz Hz True RMS True RMS Range 400mV 4V 40V 400V 1000V Resolution 100µV 1mV 10mV 100mV 1V Max Display Accuracy 400.0 ±(0.25% +5) 4.000 ±(0.4% +1) 40.00 ±(0.25% +1) 400.0 1000 Input Impedance: 10MΩ (over 1000MΩ in 400mV range) To Measure DC Voltage: 1. Plug the black test lead into the COM port and the red test lead into the VΩHz port. 2. Set the rotary switch to the V position. 3.
DC Current Frequency/RPM Circuit Connection: Circuit Connection: Hz Hz True RMS True RMS Range Resolution 40mA 400mA 10A 10µA 0.1mA 10mA Max Accuracy Voltage Display Burden 40.00 ±(0.6% +2) 200mVmax 400.0 ±(0.7% +2) 2Vmax 10.00 ±(1.0% +2) 2V max Overload Protection: 1A (500V) fast blow fuse for A input 16A (500V) fast blow fuse for A input To Measure DC Current: 1. Plug the black test lead into the COM port and the red test lead into the mA or A port. 2.
Frequency with ˜ Hz Switch Resistance (Ohms) Circuit Connection: Hz Hz True RMS True RMS Function AC Voltage AC Current Range 400mV 4V 40V 400V 750V 40mA 400mA 10A Sensitivity 40mV rms 0.2V rms 2V rms 20V rms 200V rms 8mA rms 80mA rms 8A rms Accuracy 0.01% reading +5 digits To Measure Frequency with the Hz Switch This switch is used to quickly view frequency during a measurement of AC voltage or current. 1. Push ~ Hz during an AC voltage or current measurement. 2.
Range Guide for Ohms (Ω): 300 = Meter indicates actual resistance 3k = Multiply meter display reading by 1,000 to acquire actual resistance. 30k = Multiply meter display reading by 1,000 to acquire actual resistance. 300k = Multiply meter display reading by 1,000 to acquire actual resistance. 3M = Multiply meter display reading by 1,000,000 to acquire actual resistance 300M = Multiply meter display reading by 1,000,000 to acquire actual resistance.
Diode Testing Capacitance Circuit Connection: Hz Hz True RMS True RMS Function Resolution Accuracy Max. Test Max. Open Current Circuit Voltage 1mV +(1.5% +5)* 1.5mA 3V * For 0.4V to 0.8V. Overload Protection: 600V rms max Diode Check: To ensure a proper functioning diode, the meter will develop a voltage across the component from a test current. The diode test function allows measurements of forward voltage drops across diode and transistor junctions. 1.
Continuity Check General Specifications Circuit Connection: LCD Display: Bar Graph Display: Polarity Indication: Overrange Indication: Low Battery Indication: Hz Size (WxHxD): True RMS Sampling: To Verify Continuity: A continuity test ensures that all circuit connections are intact. 1. Plug the black test lead into the COM port and the red test lead into the VΩHz port. 2. Set the rotary switch to the Ω position. 3. Press the blue button until is shown in the display. 4.
Maintenance Warning To avoid electrical shock, remove test lead before opening the cover. Repairs or servicing not covered in this manual should only be performed by qualified personnel. Battery Installation or Replacement: The #61-480 is powered by one 9V battery. 1. Remove the test leads from the front terminals and turn the meter off. 2. Remove the screw from the battery cover and lift to remove. 3. Lift battery box and replace batteries. 4.