User Guide

87
DC Voltage
Range Resolution Max Accuracy Models
Display
200mV 0.1mV 199.9 ±(0.5%+1) 61-700
2000mV 1mV 1999 ±(0.5%+1) 61-700, 61-702
20V 10mV 19.99 ±(0.5%+1) 61-701
200V 0.1V 199.9 ±(0.5%+1) 61-700, 61-702
600V 1V 600 ±(0.5%+1) 61-700
1000V 1V 1000 ±(0.5%+1) 61-702
To Measure Voltage:
5. Plug the black test lead into the COM port and the red test
lead into the + port.
6. Set the rotary switch to appropriate VAC or VDC range.
7. Connect the meter in parallel with the load or circuit.
8. Measure the voltage
Frequency
Range Resolution Max Accuracy Model
Display
2k~40kHz 1Hz 40.0 ±(0.1%+3) 61-700,
61-701
To Measure AC Current:
1. Set the rotary switch to the appropriate AAC range.
2. With the jaws closed, separate one wire from a bundle using
the long fixed jaw.
3. Slide the wire to the corner where the two jaws meet, then
open the jaws to let it in.
4. Measure the current in only one wire at a time.
AC & DC Volts
AC Voltage
Range Resolution Max Accuracy Models
Display
2000mV 1mV 1999 ±(1.2%+3) 61-702
200V 0.1V 199.9 ±(1.2%+3) 61-700, 61-701,
61-702
600V 1V 600 ±(2%+5) 61-700, 61-701
750V 1V 750 ±(2%+5) 61-702
Frequency response: 50Hz - 500Hz; ±(2%+5) 500Hz - 1KHz;
50Hz - 500Hz on 600V and 750V ranges.