User Guide
12
Temperature Measurement
Temperature Range Resolution Accuracy
-50 to –400°F 0.1°F ±(1% +3)
-400 to 1000°F 1°F
Overload Protection: 600VAC
To Measure Temperature
1. Turn the rotary switch to °F.
2. Connect the adapter with the – side into the COM terminal,
and the + side into the + terminal. (61-XXX; not supplied)
3. Insert the K type thermocouple into the adapter. (61-XXX;
not supplied)
4. If the meter is in auto-ranging mode, the range will be auto-
matically selected.
5. If the meter is in manual ranging mode, press the range but-
ton to select the desired range.
6. Measure temperature
Resistance and Continuity Measurement
Resistance Resolution Accuracy Audible
Range Continuity
40-400Ω 0.1Ω ±(1% + 2) <40__
Open voltage 0.4V
AC+DC Watt Measurement
AC+DC Watt Range Resolution Accuracy
(250V max)
40kW 0.01kW ±(2.5% +5)
400kW 0.1kW
AC+DC Watt Range Resolution Accuracy
(600V max)
400kW 0.1kW ±(2.5% +5)
1200kW 1kW
Overload Protection: 600VAC
To Measure AC+DC Watts
1. Set the rotary switch to KW/600V or KW/250V.
2. Push and hold the DCA Zero button until the reading shows zero.
3. Insert the black test lead into the COM terminal and the red
test lead into the + terminal
4. Connect the test leads to the circuit with the black lead to
neutral, and the red lead to the active line.
5. Clamp around the active line.
6. If the meter is in auto-ranging mode, the range will be auto-
matically selected.
7. If the meter is in manual ranging mode, press the range button
to select the desired range.
8. Measure AC+DC Watts
11
O
U
T
P
U
T
1
m
V
/
A
12
0
0
K
W
250
0
A
210
0
A
OF
F
K
W
60
0
V
K
W
250V
V
A
A
V
°F
D
C
A
/
W
Z
E
R
O
R
E
L
M
I
N
M
A
X
®
R
A
NGE
HOLD
CA
T
I
I
I
- 60
0
V
Power Clamp
True RMS
61-800