User Guide

5. If the meter is in manual ranging mode, press the range
button to select the desired range.
6. Measure AC voltage.
DC Voltage Measurements
DC Voltage Resolution Accuracy Input Impedance
Range
400mV 0.1mV ±(1.5% +3) 10M
4V 1mV 5M
40V 10mV
400V 100mV
600V 1V
Overload Protection:800V
To Measure DC Voltage
1. Set the rotary switch to __V.
2. Insert the black test lead into the COM terminal and the red
test lead into the + terminal.
3. Connect the test probes in parallel with the load or circuit.
4. If the meter is in auto-ranging mode, the range will be auto-
matically selected.
5. If the meter is in manual ranging mode, press the range
button to select the desired range.
6. Measure DC voltage.
10
To Connect to a Monitoring Device
1. The analog output of the meter is proportional to the current
measurement (1mV/A).
2. Connect the monitoring device to the input terminals of the
power clamp meter. The red terminal is positive and the
black terminal is negative .
3. Connect these two terminals to an oscilloscope, chart
recorder or data logger to observe the wave form, or record
the data for future analysis.
AC Voltage Measurements
AC Voltage Resolution Accuracy Accuracy Input
Range (50/60Hz) (40-1kHz) Impedance
4V 1mV ±(1.5% +5) ±(2.0% +5) 5M
40V 10mV
400V 100mV
600V 1V
Overload Protection: 800V
TRMS Measurements on AC Range
Accuracies specified at Crest Factor <3
To Measure AC Voltage
1. Set the rotary switch to __V.
2. Insert the black test lead into the COM terminal and the red
test lead into the + terminal.
3. Connect the test probes in parallel with the load or circuit.
4. If the meter is in auto-ranging mode, the range will be auto-
matically selected.
9