User Guide

Testing Diodes ( / ):
Slide the function switch to the Ω/ / position.
Note: The measurement mode defaults to Ohms (Ω).
Press the Ω/ / button twice to toggle to the Diode test mode. The meter
display should show the / in the upper right corner.
Ensure the circuit is de-energized to prevent inaccurate readings.
Apply the red test lead to the anode of the diode and the black lead to the
cathode (gray ring). Verify the forward voltage drop is about 0.6V for silicone.
Reverse the test lead connections. Verify an "OL" reading in the display.
If the diode is shorted, 0mV will be displayed.
If the diode is opened, "OL" will be displayed both directions.
Note: Audible indication occurs at <0.25V.
Battery Replacement:
Ensure test leads are disconnected from any
circuit or components.
Remove the screw from the battery cover.
Remove the battery cover.
Replace batteries with two 1.5V button cell
batteries.
Assemble the back case on the meter and re-tighten the screw.
Maintenance:
Clean the case with a damp cloth and mild detergent. Do not use abrasives or
solvents.
Service, and Replacement Parts:
No user-serviceable parts.
For replacement parts or to inquire about service information contact
IDEAL INDUSTRIES, INC. at 1-877-201-9005 or visit our website
www.testersandmeters.com.
Specifications:
Display: 3-1/2 digit LCD with 2000 counts
Polarity: Automatic, positive implied, (-) polarity indication.
Overrange: "OL" indication in display.
Measurement Rate: 2 times per second, nominal.
Auto Power Off: Approximately after 10 minutes of non-use
Battery Life: 70 hours continuous with alkaline
Low Battery Indication: The " " is displayed when battery voltage drops
below operating level.
Altitude: 6561.7 ft. (2000m)
Accuracy: Stated accuracy at 23°C ±5°C, < 75% R.H.
Power Supply: (2) 1.5V button cell batteries (NEDA 1166A, IEC LR-44).
Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% R.H.
Storage Environment: -4°F to 140°F (-20°C to 60°C) at < 80% R.H.
Dimensions: 4.9"H x2.4"W x0.9"D
(125mm H x60mm W x24mm D)
Weight: 3.9 oz (110g)
Accessories included: Built-in Test Leads, (2) 1.5V button cell batteries,
operating instructions.
Safety: Complies with UL 61010B-1, UL61010B-2-031,
EN 61010-1, EN61010-2-031, Cat II-600V,Cat III-300V
CUS
N12966
5 6
ND 4950-3 61-605 Instructions 10/27/06 9:32 AM Page 5