RC-955Display
1. Bright,2-digitLEDdisplay.(180°Rotating)
2. Displaysthepoweredlinestatusreceived
fromthetransmitter.
3. “0-99”numericindicationof
signalstrength.
4. Indicatorlightswhenaudibletone
isdisabled.
5. Peakdetectorshowsinstantaneous
changesinsignalstrength.
RC-959Display
1. Super-brightOLEDdisplay(90°rotating).
2. Displaysthepoweredlinestatusreceived
fromthetransmitter.
3. IndicatesOn/Offstatusofthe
audibletone.
4. LowBatteryIndicator.Flashes
when10%batteryliferemains.
5. “0-99”numericindicationofsignalstrength.
6. Displaysthesensitivitysetting.
7. Peakdetectorshowsinstantaneouschangesinsignalstrength.
AdditionalNotes
• Sensitivitymodeselection–generalguidelines:
• Startoutatmaximumsensitivity()untilthereceiverfindsthecircuitunder
test.Ifthereceiveristoosensitive,thenreducethesensitivityusingthe
buttonuntilthereceiver’sdisplaydoesnotpegat“99”continuously.
• Usemodefortracing:(a)inclosedcircuitswhileusingtheoutletplug
adapter(ratherthanthe25’leadandaremotereturnpathsetup),(b)inopen
circuits,(c)underground,(d)andanywhereelsemoresignaldetectionisneeded.
• Usemodetoreducethelevelofsensitivityifthehighestsensitivityrange
hassignalsaturation(displayispeggingat“99”continuously).
• Usemodefortracing(a)inclosedcircuitswhileusingthe25’leadanda
remotereturnpath,(b)andwhenpreviousmodehassignalsaturationof“99.”
• UseBreakermodefor(a)identifyingcircuitbreakersandfuses,(b)
pinpointingindividualwiresfromabundle,(c)andwhenpreviousmodehas
signal saturation.