User Manual
Page 20
3) Plugtheclampintothebatterypack.
4) Setthereceivertothehighestsensitivity()modeandtracetheconduit.Ifthe
Receiverissaturated,reducethesensitivityrange.
Tracingindustrialcontrolcircuits.
1) Ensurethatthecircuitisenergized(closedatthepanel)ataminimum.Tomaximizethe
signal,closetheotherendofthecircuitbyturningonaload,suchasamotororpump.
2) Clamparoundthehotwireofthisenergized(closed)circuit.
3) Usethemagneticstraptohangthebatterypackontothepanelor themotorcontrol
cabinet.
4) Plugtheclampintothebatterypack.
5) Setthereceivertothehighestsensitivity()modeandtracethecircuittotheother
end.Ifthereceiverissaturated,reducethesensitivitymode.
Battery Replacement
Note:Useonlygoodqualityalkalinebatteriesformaximimumoperatinglife.
Alwaysreplacewithacompletesetofnewbatteriesofthesametype.
Removebatteriesassoonastheybecomeexhaustedtoavoid
damageduetoleakage.
Transmitter:
Ensurethatthetestleadsareremovedfromtheoutput
jacksandthecircuitundertest.
1) Removethebatterycapbylooseningthescrew.
2) Replacebatterieswith(4)newAAbatteries.
3) Re-fitcapandre-tightenthescrew.