Instructions / Assembly

14
V
INSULATION
PASS
RECALL PI/DAR
TEST
MΩ
COMP STORE LOCK
61-797
>600V
COM
OFF
50V
V
100V
250V
500V
1000V
FUSED
CAT. IV
600V
0
LPF
L
e
a
k
a
g
e
C
u
r
r
e
n
t
TEST
TEST
Power-up options:
Press button while turning meter on from OFF position.
Lock button: display of the software version.
Store button: reset all stored data.
Blue button: disable auto power off.
Battery and Fuse Replacement
Refer to the following figure to replace fuse and batteries.
Testing the Fuse
CAUTION:
Use only a fuse with the
amperage, interrupt, voltage,
and speed rating specified.
Fuse rating : Fast, 315mA,
1000V, Min Interrupt
Rating 10000A.
Replace the batteries as
soon as the low battery
indicator “ ” appears,
to avoid false readings.
When the battery is too low
for reliable operation, the meter
displays “bAtt.” The meter will
not operate at all until the battery
is replaced.
1.5V x 4 alkaline batteries.
Remove the test leads before
testing the fuse.
If the display is reading FUSE,
the fuse is bad and should be
replaced.