Use and Care Guide

Form number TM61773-5 Rev 3 July 2010
Page 4
61-773
Function /
Range
Ranges
Accuracy
AC Voltage
(True RMS)
(45-400Hz)
0.0V ~ 600.0V, 45Hz - 100Hz
1.0% + 5 digits
600.0V ~ 750.0V, 45Hz - 100Hz
1.5% + 5 digits
0.0V ~ 750.0V, 100Hz - 400Hz
6.0% + 5 digits
DC Voltage
0.0V ~ 600.0V
1.0% + 5 digits
600.0V ~ 999.9V
1.5% + 5 digits
AC Current
(True RMS)
(45-400Hz)
0.0A ~ 999.9A, 45Hz - 60Hz
2.0% + 5 digits
0.0A ~ 999.9A, 60Hz - 400Hz
6.0% + 5 digits
Resistance
0.0 ~ 999.9 , 1000 ~ 9999
1.5% + 5 digits
Capacitance
0.0µF ~ 999.9uF
5.0% + 10 digits
Frequency
20.0Hz ~ 400.0Hz (Auto-ranging)
0.5% + 5 digits
Continuity
<30 on Continuity
Not specified
61-775
Function /
Range
Ranges
Accuracy
AC Voltage
(True RMS)
(20-400Hz)
0.0V ~ 100.0V, 20Hz - 100Hz
1.0% + 5 digits
100.0V ~ 600.0V, 45Hz - 100Hz
1.0% + 5 digits
600.0V ~ 750.0V, 45Hz - 100Hz
1.5% + 5 digits
0.0V ~ 750.0V, 100Hz - 400Hz
6.0% + 5 digits
DC Voltage
0.0V ~ 600.0V
1.0% + 5 digits
600.0V ~ 999.9V
1.5% + 5 digits
AC Current
(True RMS)
(20-400Hz)
0.0A ~ 999.9A, 20Hz - 100Hz
2.0% + 5 digits
0.0A ~ 999.9A, 100Hz - 400Hz
6.0% + 5 digits
DC Current
0 ~ 999.9A
2.0% + 5 digits
Resistance
0.0 ~ 999.9 , 1000 ~ 10000
1.5% + 5 digits
Capacitance
0.0µF ~ 999.9uF
5.0% + 15 digits
Frequency
20.0Hz ~ 400.0Hz (Auto-ranging)
0.5% + 5 digits
Continuity
<30 on Continuity
Not specified
AC Converter: 61-773, 61-775 True RMS sensing
Overload Protection:
AC and DC Voltage: Not to exceed 1000V DC or 750VAC RMS
AC Current: Not to exceed 1000A AC
DC Current: Not to exceed 1000A DC
Resistance: Not to exceed 600V DC or VAC RMS
Capacitance, Frequency, Continuity: Not to exceed 600V DC or VAC RMS
1
Frequency Sensitivity: 5V rms on AC VOLTS range
Frequency can be measured through clamp head.
( 5AAC at 20 to 100Hz ) ( 10AAC at 100 to 400Hz ),
Frequency Overload protection: 1000AAC, 1000VDC or 750VAC rms