Instructions / Assembly

NCV
Indications
Ranges (V AC)
Mode
12-25V 26-34V 35-45V 46-54V 55-1000V
Low
(12-1000V AC)
(Audible
Notification)
(61-657 Only)
Red
Flashing
Light in
Tip and
beeps @
2Hz
Red
Flashing
Light in
Tip and
beeps
from 2Hz
to 4Hz
Red
Flashing
Light in Tip
and beeps
@ 4Hz
Red
Flashing
Light in Tip
and beeps
from 4Hz
to 12 Hz
Red Flashing
Light in Tip
and beeps
@ 12Hz
High
(50-1000V AC)
(Audible
Notification)
No Light
in Tip, No
beeps
No Light
in Tip, No
beeps
Red
Flashing
Light in Tip
and beeps
@ 2Hz
Red
Flashing
Light in Tip
and beeps
from 2Hz
to 12 Hz
Red Flashing
Light in Tip
and beeps
@ 12Hz
Low
(12-1000V AC)
(Audible
Notification
Disabled)
(61-657 Only)
Red
Flashing
Light in
Tip @
2Hz, No
beeps
Red
Flashing
Light in
Tip from
2Hz to
4Hz, No
beeps
Red
Flashing
Light in Tip
@ 4Hz, No
beeps
Red
Flashing
Light in Tip
from 4Hz
to 12Hz,
No beeps
Red Flashing
Light in Tip
@ 12Hz, No
beeps
High
(50-1000V AC)
(Audible
Notification
Disabled)
No Light
in Tip, No
beeps
No Light
in Tip, No
beeps
Red
Flashing
Light in Tip
@ 2Hz, No
beeps
Red
Flashing
Light in Tip
from 2Hz
to 12Hz,
No beeps
Red Flashing
Light in Tip
@ 12Hz, No
beeps
Indication Response Default Function Operation
On Off Meter On RED LED Push Button
Audible Beeps On Push Button
Flashlight Flashlight On Off Push Button
Sensing Range Red LED High Range Push Button
Functions Operation Table
13
NCV Sensing Indications Table
Note: Indications above may be subject to variability caused by humidity, insulation
thickness, distance, and other factors.