Install Instructions

Functions Indication Table
Function Description
LCD 600 count LCD. Displays a “-” symbol for all negative readings, displays
“AC” for alternating current or “DC” for direct current.
LCD Backlight White backlight.
Flashlight White flashlight works independently of LCD backlight.
High Voltage
Alarm
1) Effective setting: ACV / DCV.
2) In ACV/DCV, voltage measurement value: when measuring >30V AC or
30V DC, LCD displays high voltage and PPE. The Red LED illuminates, a
PPE icon will appear in the screen and the buzzer will beep for one second.
Note: For models with SN earlier than 2110XXXX, only the PPE
icon will appear. The Red LED will not illuminate and there is
NO beep.
3) If 600V AC/DC is exceeded, the LCD displays “OL”, the buzzer beeps
On/Off continuously and the high voltage alarm (PPE symbol) is displayed.
Over Range
Indication
LCD displays “OL” when over range is encountered.
Low Battery
Indication
The “ ” symbol appears in the LCD display with insufficient
voltage. Then the buzzer beeps for 5 seconds and the unit powers down.
This ensures accurate readings.
APO The meter automatically beeps 5 times and powers down after 15 minutes
of detecting no activity in any of the three following modes; Voltage Test,
NCVT, or Continuity.
16