Instructions / Assembly
4
3
Neon Bulb
100-600V AC/DC
LEDs (61-076)
5-600V AC/DC
Continuity
Indicator
120-600V AC/DC
Features:
• VibrationModewithindicatormovement
• Auto-SwitchingVoltage/Continuity
Technology(61-076,61-080)
• Independentsolenoidandelectroniccircuitry
design provides back-up voltage indication
for added safety
• LowImpedance
• ReplaceableTestLeads
• Shieldedprobetips
• Ultrasonicallyweldedando-ringsealedfor
added durability
• Indicates:
•100-600VAC/DC(61-065,61-067)
• 5-600VAC/DC(61-076,61-080)
To Measure AC/DC Voltage:
• Ensurethattheplugforthetestleadsisfully
seatedintothebananajacks.
• Connectthetesterinparallelwiththeloador
circuit.
• Thetesterindicatesthevoltagetype,DC
polarity, and the voltage level.
Warning
Donotexceeddutycyclespecifiedontester.
To Test for Continuity (61-080,61-076):
• Ensurethattheplugforthetestleadsisfully
seatedintothebananajacks.
• Testforcontinuitybyconnectingthetesterto
the de-energized circuit.
• Ifcircuithas<500kΩ,theContinuityLED
lights.
• Reversingprodsonthecircuitundertest
verifiescontinuityversuslowvoltage+DC.
Applications:
• LocatingBlownFuses
With power off (61-076,
61-080):Placetesteracross
the suspected fuse to
perform continuity check.
IfcontinuityLEDlights,the
fuseisgood.Ifnot,the
fuse is defective.
Withpoweron:Placetesteracrossthe
“source”sideofonefuseandtheloadside
ofanadjoiningfuse.Ifnoorlowvoltageis
indicated, the fuse next to the load side prod is
blown.Iflinevoltageisindicated,thefuse
nexttotheloadsideprodisOK.Repeatthe
same test with the prods on the opposite side
of the same two fuses to check the other fuse.