User Guide

3
Remove the test leads from the circuit prior to
removing battery cap.
Do not attempt to repair this unit as it has no
userserviceable parts.
Voltages exceeding 30VAC or 60VDC pose a
shock hazard so use caution.
CAUTION
To protect yourself, think “Safety First”:
Use appropriate personal protective equipment
such as safety glasses, face shields, insulating
gloves, insulating boots and/or insulating mats.
Before each use.
- Perform a continuity test by touching the test
leads together to verify the functionally of the
battery and test leads.
- Use the 3 Point Safety Method. (1) Verify
meter operation by measuring a known
voltage. (2) Apply meter to circuit under test.
(3) Return to the known live voltage again to
ensure proper operation.
Never ground yourself when taking electrical
measurements.
Connect the black common lead to ground or
neutral before applying the red test lead to
potential voltage. Disconnect the red test lead
from the voltage first.
Always work with a partner.
When using the probes, keep fingers as far
behind the probe tips as possible.
Never connect a source of voltage with the
function rotary switch in Ω/ :</ A //Hz
position.Never set the meter in A function
to measure the voltage of a power supply
circuit in equipment that could result in
damage to the meter and the equipment
under test.