SDS
Technical Specification
2010 / 04 / 15
GP001-G6F22-04 5 - 12
9. Caution for Use
1. Since the battery is not manufactured for recharging, there are risks of electrolyte leakage
or causing damage to the device if the battery is charged.
2. The battery shall be installed with its "+" and "-" polarity in correct position, otherwise may
cause short-circuit.
3. Short-circuiting, heating, disposing of into fire and disassembling the battery are
prohibited.
4. Battery cannot be forced discharge, which lead to excess internal gas generation and,
may result in bulging, leakage and de-crimping of cap.
5. New and used batteries cannot be used at the same time, when replaced batteries
recommend to replace all and with the same brand type.
6. Exhausted batteries should be removed from compartment to prevent over-discharge,
which cause leakage & damage to the device.
7. Direct soldering is not allowed, which will damage the battery.
8. Battery should be kept out of the reach of children to prevent swallow, in case of accident
should contact physician at once.
9. The battery should not be dismantled and deformed.
10. Shelf Life 1 year after delivery under proper storage conditions
1
Storage Conditions
Temperature 20 ± 2°C Relative humidity 65 ± 20% RH
11. Discharge Curves :
Test temperature /
20 ± 2°C
1) 180Ω, 0.5 hrs/day (4.8V)
Fig 1
Discharge Method(EPV) / ( ) :
2) 620Ω, 2 hrs/day (5.4V)
Fig 2
12. Battery Dimension and Structure Refer to Drawing DWG-S-002
DWG-S-002