SDS
Technical Specification
2010 / 04 / 15
GP001-G6F22-04 3 - 12
6. Electrical Characteristics
Test Conditions tested within 30 days after delivery
30
load resistance temperature Measuring time
620Ω ± 0.5%
20 ± 2°C 0.3 sec
Off-load voltage
(V)
On-load voltage
(V)
Test Specification
New Battery
9.60 9.30
MIL-STD-105E, Class II,
Double Sampling, AQL=0.4
After 3 mth. at temp=45
45 3
9.40 9.10
MIL-STD-105E, Class II,
Double Sampling, AQL=0.4
After 12 mth room temp
12
9.40 9.10
MIL-STD-105E, Class II,
Double Sampling, AQL=0.4
7. Service Output
Test Conditions tested within 30 days after delivery
30
Temperature 20 ± 2°C
Discharge Condition Average Minimum Discharge Time
Standard
Discharge
load
Daily
discharge
time
End
Point
Volta
g
e
(V)
New
Battery
After 3 mth. at
temp=45°C.
45°C
3
After 12 mth. at
room temp.
12
IEC
620Ω
2 hrs 5.4 26 hrs 20.8 hrs 23.4 hrs
IEC
270Ω
1 hrs 5.4 8 hrs 6.4 hrs 7.2 hrs
IEC
180Ω
0.5 hrs 4.8 6.5 hrs 5.2 hrs 5.8 hrs
REF
620Ω
24 hrs 5.4 14 hrs 11.2 hrs 12.6 hrs
Acceptance Criteria / :
(1) 9 pieces of battery will be tested for each discharging standard.
9
(2) The result of the average discharging time from each discharging standard shall be
equal to or more than the average minimum time requirement; and no more than
one battery has a service output less than 80% of the specified requirement.
80%
1
(3) One re-test is allowed to confirm the previous result.