Install Instructions
6
Coaxial Installation Steps
Step 3 – Terminate
Compression F-Style
Press the connector onto the cable until the white dielectric
is even with the center hole of the connector.
Place the prepared connector completely into the tool’s compression
chamber. When the connector is in place, squeeze the tool handles
together until the connector is fully compressed.
Step 4 – Testing
Test the cable with a continuity tester to make sure the connector
is properly terminated with no opens or shorts. One common failure
occurs when a small strand of uncut braiding comes in contact with
the center conductor after termination, causing a short in the cable.
Finished connector
CAT NO. 30-603
LinkMaster Pro XL
CAT. NO. 33-880
VDV MultiMedia Tester
CAT. NO. 33-856
Crimp F-Style
Insert stripped cable into connector until the white dielectric
is even with the center hole. Crimp per the tool’s instructions.
Compression BNC
Insert stripped cable into BNC connector
until the white dielectric reaches a point
where you can feel the center conductor
connect with the inner center pin socket.
Compress per your tool’s guidelines.
(NOTE: To help approximate how much
cable to push into the connector for the center
conductor to make contact, you can do the
following: Hold stripped cable against the con-
nector as shown in photo to the right. End of
center conductor should line up with top of the
knurled ring of connector. Mark cable where
it meets end of conductor. This mark shows
how far to insert cable fully seat conductor.)