Cut Sheet

A-27
1-800-435-0705 CUSTOMER ASSISTANCE WWW.IDEALINDUSTRIES.COM
Wire TerminaTion
sTreeTLiGhT KiTs
Insulation Stranded* Ordering
Diameter Range Conductor Type Code
(Inches) Size (AWG) (
CHOOSE 1)
12-6 Copper Crimp U –
12-6 Aluminum Crimp UA –
.120-.430
4 or 2 Copper Crimp LC –
4 or 2 Aluminum Crimp LA –
Insulation Ordering Stranded* Ordering
Diameter Range Code Conductor Type Code
(Inches) (
CHOOSE 1)
Size (AWG) (
CHOOSE 1)
10 Copper Crimp 6 –
.155-.430 ADB 8 Copper Crimp 4 –
6 Copper Crimp 3 –
4 Copper Crimp 2 –
.420-.785 EAFB 2 Copper Crimp 1 –
1 Copper Crimp 0 –
1/0 Copper Crimp 10 –
.155-.430 ADB 10 1 –
8 1 –
6 Terminal Block 1 –
4 with Set Screws 1 –
2 Copper or Alum. 1 –
.420-.785 EAFB 1 Conductors 10 –
1/0 10 –
LINE SIDE LOAD SIDE
Insulation Equivalent Conductor Size Ordering
Diameter Range Conductor Size (AWG) Type Code
(Inches) (See Table) (
CHOOSE 1)
10 Copper Crimp 6
8 Copper Crimp 4
.120 -.430 1 6 Copper Crimp 3
4 Copper Crimp 2
2 Copper Crimp 1
1 Copper Crimp 0
Terminal Block
Copper or
.120 -.430 1 10-2 Aluminum N/A
Conductors
NOTE:
Fused kits require a 13/32” x 1 1/2” fuse. DO NOT USE GLASS OR INDICATING TYPES.
Waterproof or direct burial wire is recommended. THHN is NOT recommended.
*
For solid wire: 14-4 AWG, use codes U, UA, C, or A. 2 AWG, use codes LC or LA.
75°C / 600 Volts Max.
Example:
A Y-Tap Kit with set screws for a 2 AWG phase line side conductor with a
diameter of .472” and a 10 AWG copper load side conductor is ordered as
an 82S-EAFB1-C.
Insulation Equivalent Stranded* Ordering
Diameter Range Conductor Conductor Type Code
(Inches) (See Table) Size (AWG) (
CHOOSE 1)
12-6 Copper Crimp U
12-6 Aluminum Crimp UA
.120-.430 1
4 or 2 Copper Crimp LC
4 or 2 Aluminum Crimp LA
NOTE: It is not necessary to use the load side ordering code if it is the same
as the line side code, i.e., a 65U-U is ordered as a 65U.
Insulation Equivalent Stranded* Ordering
Diameter Range Conductor Conductor Type Code
(Inches) (See Table) Size (AWG) (
CHOOSE 1)
12-6 Copper Crimp C
.120 -.430 1 12-6 Aluminum Crimp A
4 or 2 Copper Crimp LC
12-6 Copper Crimp C
12-6 Aluminum Crimp A
.120 -.430 1
4 or 2 Copper Crimp LC
4 or 2 Aluminum Crimp LA
Insulation Ordering Stranded* Ordering
Diameter Range Code Conductor Type Code
(Inches) (
CHOOSE 1)
Size (AWG) (
CHOOSE 1)
10 Copper Crimp 6 –
.155-.430 ADB 8 Copper Crimp 4 –
6 Copper Crimp 3 –
4 Copper Crimp 2 –
.420-.785 EAFB 2 Copper Crimp 1 –
1 Copper Crimp 0 –
1/0 Copper Crimp 10 –
.155-.430 ADB 10 1 –
8 1 –
6 Terminal Block
1 –
4 with Set Screws 1 –
2 Copper or Alum. 1 –
.420-.785 EAFB 1 Conductors 10 –
1/0 10 –
LR32565