Cut Sheet
E-26
WWW.DEALINDUSTRIES.COM 1-800-435-0705 CUSTOMER ASSISTANCE
DATACOMM/NETWORKS
OTDR
33-960 Series – Micro OTDRs
Designedwithinstallersinmind,33-960SeriesMicroOTDRsofferexcellentperformance
andeaseofuseinatrulyhandheld,lightweightandruggedpackage.Availableaseitheran
850/1300nm(multimode)or850/1300/1310/1550nm(multimodeandsinglemode)OTDR,
theyareideallysuitedfortheinstallationandtroubleshootingofLAN,campusandWANber
networks.Bothmodelscombinehighmeasurementprecisionwiththeuserfriendlinessof
one-button operation resulting in accurate characterization of connectors and splices in
additiontofastandreliablefaultlocation.
WiththeMBoption,theseOTDRsprovideclearPASS/FAILindications.Distance,lossandORL
foreacheventisreportedinatracesummarytablemakingfullcerticationofthelinkpossible.
EachOTDRisshippedinakitcontainingeverythingyouneedtogetstartedonthejob,including
aruggedizedcarryingcase,PCsoftware,rechargeablebatteriesandwallcharger.
• Short Attenuation and Event Dead Zones — for accurate location and characterization of events
• Autotest Function — provides simple one-button operation
• Fast Data Acquisition — important for troubleshooting intermittent problems
• Certifying OTDR Option — for tier-2 certification
• Optional Macro Bend detection — accurately detects macro bends in singlemode fiber
Specifications
Testing 33-960-10 33-960-30
Wavelength [nm] 850, 1300 850, 1300, 1310, 1550
Dynamic Range [dB]
24 / 25 24 / 25 / 29 / 28
Attenuation dead zone [m] 11 / 11 11 / 11 / 11 / 12
Pulse width [ns] 10, 30, 100, 275, 1000, 2500, 10000
Event dead zone [m] 2.5 worst case
Launch Conditions (MM) Class CPR 1 or 2
Linearity [dB / dB] ± 0.03
Loss threshold [dB] 0.05
Loss resolution [dB] 0.01
Sampling resolution [m] 0.16 to 5
Sampling points Up to 30000
Typical real time refresh
[1/sec ]
4
Distance uncertainty [m]
± (0.75 + 0.0025% x distance +
sampling resolution)
Distance range [km]
0.1 to 40
MM: 0.1 to 40 SM: 0.65
to 160
Stable source output power
[dBm]
-1.5 MM: -1.5 SM -6.5
Laser Safety
21 CFR 1040.10 and IEC 60825-
1:1993+A2:2001 / Class 1M
Hardware All Models
Memory capacity 500 traces
Data connectivity USB A and USB B
Size (HxWxD) [mm] 250 x 125 x 75 (9.8 x 4.9 x 2.9 in.)
Weight 1 kg (2.2 lbs.)
Temperature
Operating: -18°C to 50°C ,
Storage: -40°C to 70°C
Batteries 2 x Li-Ion
Power supply (mains) 110 – 230 V AC
Power supply (unit) 9 - 24 V DC, 12 Watt
Operating time
8 hours (per Bellcore
™ TR-NWT-001138)
Warranty 1 year
Kits
33-960-10 MM OTDR Kit 33-960-30 Quad OTDR Kit
MM OTDR with 850/1300nm Quad OTDR with
850/1300/1310/1550nm
Ruggedized carrying case
Ruggedized carrying case
PC-Software PC-Software
CD with manual and Quick
Reference Guide
CD with manual and Quick
Reference Guide
Wall charger Wall charger
2 Li-Ion rechargeable batteries 2 Li-Ion rechargeable batteries
SC Adapter 1 SC and 1 FC Adapter
33-960-10MB OTDR Kit with Tier 2
certification option and macro
bend detection
33-960-30MB
Ordering Information
Description Cat. No.
200x and 400x video probe w/USB port 33-960-VP
Adapter for FC connectors 33-961-10
Adapter for SC connectors 33-961-20
Adapter for ST connectors 33-961-30
Adapter for E2000 connectors 33-961-40
Adapter for DIN 47256 connectors 33-961-50
Adapter for HMS-10/AG connectors 33-961-60
Cleaning Kit 1219-00-1621
Rechargeable battery 33-960-BP
Foldable USB Keyboard 33-960-KB