Cut Sheet

E-13
1-800-435-0705 CUSTOMER ASSISTANCE WWW.IDEALINDUSTRIES.COM
COMpRESSiON CONNECTORS
Compression Connector Instructions
45-603
STEP 2
45-603
STEP 2
Compression F-Connector
Compression RG-11 F-Connector
Compression BNC/RCA Connectors
STEP 2 & 3
1
4”
1
4”
45-074
STEP 1
1. Use IDEAL Data T
®
-Cutter (45-074) to cut cable
to desired length.
2. Use IDEAL Coax Stripper (45-603 or 45-526) to
strip coax to proper dimensions.
• Properstriplengthsettingswillleave1/4”of
centerconductorexposedand1/4”of
braiding (shield) exposed.
• Afterstripping,makesuretipofcenter
conductor is straight and not bent. Straighten
conductor if necessary.
3. Foldbackouterlayerofbraiding(shield)
againstcablejacket.Keepbraidstrandsas
straightandasclosetojacketaspossible.
• Note:ForQuadShieldcables(with4layers:
outerbraid,outerfoil,innerbraid,innerfoil),
rstfoldbackouterbraiding.Use45-074to
scoreandremoveexposed1/4”ofouterfoil.
Removeouterfoil,andfoldbackinner
braiding.
1. Use IDEAL Data T
®
-Cutter (45-074) to
cut cable to desired length.
2. Use IDEAL Coax Stripper (45-111) to strip
RG-11 coax to proper dimensions.
• Properstriplengthsettingswillleave1/4”
(minimum) of center conductor exposed
and1/4”ofbraiding(shield)exposed.
• Afterstripping,makesuretipofcenter
conductor is straight and not bent. Straighten
conductor if necessary. Conductor must be
straighttomakepropercontactwithpin
contact inside of connector.
3. Foldbackouterlayerofbraiding(shield)against
cablejacket.Keepbraidstrandsasstraightand
asclosetojacketaspossible.
• Note:ForQuadShieldcables(with4layers:
outerbraid,outerfoil,innerbraid,innerfoil),
rstfoldbackouterbraiding.Use45-074
toscoreandremoveexposed1/4”ofouterfoil.Removeouter
foil,andfoldbackinnerbraiding.
45-111
45-074
STEP 1
1. Use IDEAL Data T
®
-Cutter (45-074 to cut
cable to desired length.
2. Use an IDEAL coax stripper (45-603 or 45-526)
to strip coax to proper dimensions.
• Properstriplengthsettingswillleave1/4”
(minimum) of center conductor exposed and
1/4”ofbraiding(shield)exposed.
• Afterstripping,makesuretipofcenter
conductor is straight and not bent. Straighten
conductor if necessary. Conductor must be
straighttomakepropercontactwithpin
contact inside of connector.
3. Foldbackouterlayerofbraiding(shield)against
cablejacket.Keepbraidstrandsasstraightand
asclosetojacketaspossible.
• Note:ForQuadShieldcables(with4layers:
outerbraid,outerfoil,innerbraid,innerfoil),
rstfoldbackouterbraiding.Use45-074
toscoreandremoveexposed1/4”of
outerfoil.Removeouterfoil,andfold
backinnerbraiding.
45-074
STEP 1
STEP 4
STEP 2 & 3
1
4”
1
4”
4. Push F connector on to prepared
cable until white center dielectric is
flush with bottom of the nut of the
F connector.
5. Insertconnector/cableassemblyinto
the OmniSeal
Pro XL compression
tool,squeezehandlecompletelyto
compresstting.Removecompleted
cable assembly.
STEP 4
STEP 5
4. Measureandmarkcableinsertionlength.
Align tip of center conductor with bottom of
hexnutttingofconnector.Markorlightly
scorecablejacketnearbaseofconnector.
Connectorshouldbewithin1/8”ofthismark
after it is pushed on to cable. If it is more than
1/8”awayfrommark,continue
rockingandguidingconnector
on to cable. Approximately
1-1/4”ofcablelengthshould
be inserted into connector
prior to compressing the
connector.
5. Inserttheconnector/cableassemblyinto
OmniSeal
Pro XL compression tool (adjust
plungersettingifnecessary),squeezehandle
completelytocompresstting.Remove
completed cable assembly.
STEP 2 & 3
1
4”
1
4”
STEP 4
STEP 5
4. Measureandmarkcableinsertionlength.For
BNC’s,aligntipofcenterconductorwithtopof
thenuttting.ForRCA’s,aligntipofcenter
conductorwithtopofretentioncollar.Markor
lightlyscorecablejacketnearbaseof
connector.Connectorshouldbewithin1/8”of
thismarkafteritispushedontocable.Ifitismorethan1/8”away
fromthemark,continuerockingandguidingconnectorontocable.
Approximately1-1/4”ofcablelengthshouldbeinsertedintotheconnector
priortocompressingconnectorforBNC.Approximately1-1/8”ofcable
length should be inserted into connector prior to compressing connector
for the RCA.
5. Insertconnector/cableassemblyintoOmniSeal
ProXLcompressiontool,
squeezehandlecompletelytocompresstting.Removecompletedcable
assembly.
STEP 5
STEP 2